flow-statistic frequency value-added-service statistic-type car

Function

The flow-statistic frequency value-added-service statistic-type car command configures a board to read EDSG service traffic statistics at a configured rate.

The undo flow-statistic frequency value-added-service command restores the default configuration.

By default, a board can read 52 EDSG CAR statistics at an interval of 200 ms.

This command is supported only on the NetEngine 8000 F1A.

Format

flow-statistic frequency value-added-service speed statistic-type car

undo flow-statistic frequency value-added-service [ speed statistic-type car ]

Parameters

Parameter Description Value
speed

Sets the number of EDSG services for which traffic statistics are collected every 200 ms.

The value is an integer ranging from 52 to 500.

Views

Slot view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
vas write

Usage Guidelines

Usage Scenario

To improve the statistical precision of service traffic in scenarios where CAR is performed on upstream and downstream EDSG services, run the flow-statistic frequency value-added-service command to increase the statistical rate.

Precautions

In VS mode, this command is supported only by the admin VS.

Example

# Configure the board in slot 1 to read traffic statistics about 100 EDSG services every 200 ms in scenarios where CAR is performed on upstream and downstream EDSG services.
<HUAWEI> system-view
[~HUAWEI] slot 1
[*HUAWEI-slot-1] flow-statistic frequency value-added-service 100 statistic-type car
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.