timer query (MLD view)

Function

The timer query command sets a global interval for sending Multicast Listener Discovery (MLD) general query messages.

The undo timer query command restores the default value.

By default, the interval for sending MLD general query messages is 125 seconds.

Format

timer query interval

undo timer query

Parameters

Parameter Description Value
interval

Interval for sending MLD general query messages.

The value is an integer that ranges from 1 to 18000, in seconds.

Views

MLD view, VPN instance MLD view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
igmp write

Usage Guidelines

Usage Scenario

The function of this command is the same as that of the mld timer query command used in the interface view. The configuration in the MLD view is globally valid, whereas the configuration in the interface view is valid only for the current interface. The system prefers the configuration in the interface view. The configuration in the MLD view is used only when the configuration in the interface view is not done.

Example

# Set the interval for sending MLD general query messages to 200 seconds.
<HUAWEI> system-view
[~HUAWEI] multicast ipv6 routing-enable
[*HUAWEI] mld
[*HUAWEI-mld] timer query 200
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.