ospf ldp-sync multi-area

Function

The ospf ldp-sync multi-area command enables LDP-OSPF synchronization on a multi-area adjacency interface.

The undo ospf ldp-sync multi-area command disables LDP-OSPF synchronization on a multi-area adjacency interface.

By default, LDP-OSPF synchronization is disabled on multi-area adjacency interfaces.

Format

ospf ldp-sync multi-area { area-id | area-id }

undo ospf ldp-sync multi-area { area-id | area-id }

Parameters

Parameter Description Value
area-id

Specifies the ID of an OSPF area.

The value can be a decimal integer ranging from 0 to 4294967295 or in the format of an IP address.

Views

100GE interface view, 10GE interface view, 25GE sub-interface view, 25GE interface view, 400GE interface view, 40GE interface view, 50GE sub-interface view, 50GE interface view, Eth-Trunk interface view, FlexE interface view, GE optical interface view, GE electrical interface view, GMPLS-UNI interface view, Global VE sub-interface view, Tunnel interface view, VE sub-interface view, VLANIF interface view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
ospf write

Usage Guidelines

Usage Scenario

LDP-OSPF synchronization minimizes the impact of a traffic interruption that may occur on a network with primary and backup LSPs by restricting the interruption to the millisecond level.

Prerequisites

The ospf enable multi-area command has been run.

Precautions

To display synchronization information about interfaces on which LDP-OSPF synchronization is configured, run the display ospf ldp-sync interface command.

Example

# Enable LDP-OSPF synchronization on multi-area adjacency interface.
<HUAWEI> system-view
[~HUAWEI] ospf 1
[*HUAWEI-ospf-1] area 0
[*HUAWEI-ospf-1-area-0.0.0.0] quit
[*HUAWEI-ospf-1] area 1
[*HUAWEI-ospf-1-area-0.0.0.1] quit
[*HUAWEI-ospf-1] quit
[*HUAWEI] interface GigabitEthernet 0/1/0
[*HUAWEI-GigabitEthernet0/1/0] ospf enable 1 area 0
[*HUAWEI-GigabitEthernet0/1/0] ospf enable multi-area 1
[*HUAWEI-GigabitEthernet0/1/0] ospf ldp-sync multi-area 1