ppp keepalive adjustment

Function

The ppp keepalive adjustment command configures adjustment of the number of PPP detection times.

The undo ppp keepalive adjustment command disables adjustment of the number of PPP detection times.

By default, adjustment of the number of detection times is disabled.

This command is supported only on the NetEngine 8000 F1A.

Format

ppp keepalive adjustment system-state

ppp keepalive adjustment retransmit

undo ppp keepalive adjustment system-state

undo ppp keepalive adjustment retransmit

Parameters

Parameter Description Value
retransmit

Indicates that the number of user detection failures is cleared after the board on which an Eth-Trunk member interface resides becomes a master processing board.

-

system-state

Indicates that the number of PPP detection times is adjusted based on the system status.

-

Views

Virtual template view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
pppoebras write

Usage Guidelines

Usage Scenario

If the system is busy, for example, the CPU usage exceeds 80%, and the configured PPP detection interval is less than 40s, run the ppp keepalive adjustment system-state command so that the PPP detection interval is adjusted to a value twice the configured interval.

When inter-board Eth-Trunk member interfaces alternate between Up and Down, the device may not have a master processing board for a moment, causing user logouts. To clear the number of user detection failures after the board on which a trunk member interface resides becomes a master processing board so that users will stay online, run the ppp keepalive adjustment retransmit command. This function helps adjust the number of PPP detection times.

Configuration Impact

After the ppp keepalive adjustment retransmit command is run, if inter-board trunk member interfaces alternate between Up and Down, the number of user detection failures may be slightly greater than the configured ppp keepalive.

If the ppp keepalive adjustment command is run more than once in the same view, the latest configuration overrides the previous one.

Precautions

In VS mode, this command is supported only by the admin VS.

Example

# Configure the device to adjust the number of PPP detection times based on the system status.
<HUAWEI> system-view
[~HUAWEI] interface virtual-template 10
[*HUAWEI-Virtual-Template10] ppp keepalive adjustment system-state
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >