The prefec-tca command configures an alarm threshold for FEC bit error ratio detection.
The undo prefec-tca command restores the default configuration for FEC bit error ratio detection.
By default, FEC bit error ratio detection is enabled. The default alarm association threshold, alarm clearing threshold are 100E-6, 100E-7, respectively.
Parameter | Description | Value |
---|---|---|
trigger-power |
Specifies an alarm association threshold, where:
|
|
recover-threshold recover-coefficient |
Specifies an alarm clearing threshold, where:
|
|
recover-power |
Specifies an alarm clearing threshold, where:
|
|
prefec-tca |
Indicates FEC bit error ratio detection. |
- |
trigger-threshold trigger-coefficient |
Specifies an alarm association threshold, where:
|
|
Usage Scenario
To configure an alarm threshold for FEC bit error ratio detection, run the prefec-tca command. By default, FEC bit error ratio detection is enabled. The default alarm thresholds and detection intervals are used. If the FEC bit error ratio exceeds a specified threshold, the device reports an FEC bit error ratio alarm to the NMS. When the FEC bit error ratio falls below a specified threshold, the device reports an FEC bit error ratio clear alarm to the NMS.