ptp alarm-threshold clock-class

Function

The ptp alarm-threshold clock-class command configures an alarm threshold for time source input deterioration.

The undo ptp alarm-threshold clock-class command restores the default configuration.

By default, the alarm threshold for time source input deterioration is 6.

Format

ptp alarm-threshold clock-class clock-class-value

undo ptp alarm-threshold clock-class [ clock-class-value ]

Parameters

Parameter Description Value
clock-class clock-class-value

Displays the alarm threshold of time source input deterioration.

The value is an integer ranging from 0 to 255.

Views

System view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
clksync write

Usage Guidelines

Usage Scenario

Packet bearer devices can input reference clock signals through a PTP or 1PPS+TOD interface for time synchronization. When a PTP interface is used to input reference clock signals, the clockClass of the clock source is less than the alarm generation threshold configured using the ptp alarm-threshold clock-class command, and the stepsRemoved of the clock source is 0, an alarm is generated, indicating that the input reference clock signals deteriorate. When a 1PPS+TOD interface is used to input reference clock signals and the clockClass of the clock source is less than the alarm generation threshold configured using the ptp alarm-threshold clock-class command, an alarm is generated, indicating that the input reference clock signals deteriorate.

In VS mode, this command is supported only by the admin VS.

Example

# Configure the alarm threshold of time source input deterioration as 7.
<HUAWEI> system-view
[~HUAWEI] ptp alarm-threshold clock-class 7