The radius-attribute assign class partial-match pppoe motm command configures the class attribute to be encapsulated into a PPP packet's MTOM field.
The undo radius-attribute assign class partial-match pppoe motm command restores the default configuration.
By default, a RADIUS attribute is not encapsulated into a ppp packet.
This command is supported only on the NetEngine 8000 F1A.
Parameter | Description | Value |
---|---|---|
encap-format format-sting |
Specify the encapsulating name. |
The value is a string of 1 to 31 characters. |
delimiter |
Specifies the encapsulation format and name. |
The value is a string of 1 characters. |
local |
Indicates that the local configuration is excluded. |
- |
partial-match string-value |
Specifies the character string for approximate string matching. |
The value is a string of 1 to 31 characters. |
Usage Scenario
Link Account in the Class attribute can be encapsulated in specified options in packets to be sent to the clients.
If the IETF does not define the code of an option in which a RADIUS attribute is encapsulated, you can run this command to configure the RADIUS attribute to be encapsulated in a user-defined option. If the device encapsulates a RADIUS attribute in an option with a default code and you want to encapsulate the RADIUS attribute in another option, you can run this command.Configuration Impact
The radius-attribute assign command takes effect for users who go online after the command is configured.
Precautions
In VS mode, this command is supported only by the admin VS.