The rip bfd block command blocks BFD on a specified interface.
The undo rip bfd block command disables the blocking function.
By default, the blocking function is disabled.
100GE interface view, 10GE interface view, 25GE sub-interface view, 25GE interface view, 400GE interface view, 40GE interface view, 50GE sub-interface view, 50GE interface view, Eth-Trunk interface view, FlexE interface view, GE optical interface view, GE electrical interface view, GMPLS-UNI interface view, Global VE sub-interface view, Tunnel interface view, VE sub-interface view, VLANIF interface view
Usage Scenario
If the link status is unstable, BFD sessions may frequently alternate between Up and Down, which deteriorates network stability and reliability. In this situation, run the rip bfd block command to block BFD.
Prerequisites
BFD has been enabled using the bfd command.
Precautions
The rip bfd block, rip bfd enable, and rip bfd static commands are mutually exclusive. The latest configuration overrides the previous one.