trap-threshold symbol-error high-threshold low-threshold (system view)

Function

The trap-threshold symbol-error high-threshold low-threshold command sets an upper threshold, lower threshold, and detection interval for the Symbol error alarm.

The undo trap-threshold symbol-error high-threshold low-threshold command restores the upper threshold, lower threshold, and detection interval of the Symbol error alarm to the default values.

By default, the upper threshold of the Symbol error alarm is 1000, the lower alarm threshold is 100, and the detection interval is 10 seconds.

Format

trap-threshold slot slot-id card cardid symbol-error high-threshold high-threshold low-threshold low-threshold interval-second interval

undo trap-threshold slot slot-id card cardid symbol-error

Parameters

Parameter Description Value
card cardid

Specifies the ID of a registered subcard.

-

high-threshold high-threshold

Specifies an upper alarm threshold.

The value is an integer in the range from 1 to 4294967295. The default value is 1000.

low-threshold low-threshold

Specifies a lower alarm threshold.

The value is an integer ranging from 1 to 4294967295. The default value is 100.

interval-second interval

Specifies a detection interval for Symbol error frames.

The value is an integer ranging from 1 to 65535, in seconds. The default value is 10.

slot slot-id

Specifies the ID of a slot.

-

Views

System view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
device-mgr write

Usage Guidelines

Usage Scenario

To set an upper threshold, lower threshold, detection interval for the Symbol error alarm, run the trap-threshold symbol-error high-threshold low-threshold command. After this configuration is performed, a device generates an alarm and sends it to an NMS only when the number of Symbol error frames sent or received by the device reaches the upper threshold for three consecutive detection intervals. The device sends a clear alarm to the NMS only when the number of Symbol error frames sent or received by the device falls below the lower threshold for three consecutive detection intervals.

Precautions

The configured thresholds take effect only when the Symbol alarm function is enabled. You can run the snmp-agent trap enable port symbol-error command to enable the Symbol alarm function on an interface.

The value of high-threshold must be greater than or equal to that of low-threshold.

In VS mode, this command is supported only by the admin VS.

Example

# On each interface of subcard 1 in slot 1, set the upper threshold of the Symbol error alarm to 1500, lower threshold to 150, and detection interval to 15 seconds.
<HUAWEI> system-view
[~HUAWEI] trap-threshold slot 1 card 1 symbol-error high-threshold 1500 low-threshold 150 interval-second 15