local-pw-id (VPLS PW Trace test instance)

Function

The local-pw-id command sets a PW ID for a local PE in the NQA view for VPLS PW Trace test.

The undo local-pw-id command restores the default PW ID.

If the VC type is LDP, the default PW ID is 0 for a local PE.

Format

local-pw-id pwIdValue

undo local-pw-id

Parameters

Parameter Description Value
pwIdValue

Specifies a PW ID for a local PE.

If the VC type is LDP, the value is an integer ranging from 1 to 4294967295.

Views

NQA view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
sla write

Usage Guidelines

Usage Scenario

To perform an NQA VPLS PWtrace test, run the local-pw-id command to configure a PW ID for the local PE. The PW ID must be the same as the PW ID for the remote PE.

Precautions

If parameters need to be changed during the running of the test instance, the system prompts you whether to terminate the test instance. Press "Y" or "N" as required.

  • If you press "Y", the test instance is terminated and parameters changed. The settings take effect after being committed. To restart the test instance, run the start command.
  • If you press "N", the test instance keeps running, and the parameters fail to be modified.

Example

# Set the PW ID to 100 for the local PE in the NQA view.
<HUAWEI> system-view
[~HUAWEI] nqa test-instance admin pwe3
[*HUAWEI-nqa-admin-pwe3] test-type vplspwtrace
[*HUAWEI-nqa-admin-pwe3] local-pw-id 100
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >