TRUNK/5/BACKSTATE_CHANGE

Message

TRUNK/5/BACKSTATE_CHANGE: The working status of the backup trunk changed. (TrunkName=[TrunkName], Status=[WorkState])

Description

The working status of an Eth-Trunk interface in 1:1 master/backup mode changed.

Parameters

Parameter Name Parameter Meaning

TrunkName

Name of an Eth-Trunk interface in 1:1 master/backup mode

WorkState

Working status of an Eth-Trunk interface in 1:1 master/backup mode

Possible Causes

Cause 1: The active member interface of the Eth-Trunk interface in 1:1 mode went Down, and working status of the Eth-Trunk interface was therefore changed from master to backup.

Cause 2: The active member interface of the Eth-Trunk interface in 1:1 mode restored, and working status of the Eth-Trunk interface was therefore changed from backup to master.

Cause 3: The protect-switch command was run on the Eth-Trunk interface in 1:1 mode to enable a switchover between the active and inactive interfaces.

Cause 4: Both the active and backup member interfaces of the Eth-Trunk interface in 1:1 mode went Down, and working status of the Eth-Trunk interface was therefore changed to initial.

Procedure

1. Causes 1, 2, and 3: The log is informational only, and no action is required.

2. Cause 4: Check whether the master and backup interfaces and the interfaces of the remote device were shut down.

  • If any of the interfaces was shut down, run the undo shutdown command on the interface.
  • If no interface was shut down, a link fault occurred. Replace the faulty link.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >