EOAM-1AG/1/LOC_active: MEP is disconnected with the remote MEP. (MdIndex=[MdIndex], MaIndex=[MaIndex], MdName=[MdName], MaName=[MaName], MepId=[MepId], RmepId=[RmepId])
Parameter Name | Parameter Meaning |
---|---|
MdIndex |
MD Index |
MaIndex |
MA Index |
MdName |
MD Name |
MaName |
MA Name |
MepId |
MEP ID |
RmepId |
RMEP ID |
The MEP received no CCM in a period of time 3.5 times the interval at which CCMs were sent.
Perform the following operations to check the network operating status on the MEP:
2.Run the display cfm mep [ md md-name [ ma ma-name [ mep-id mep-id ] ] ] command to view the value of the CCM Send field on the RMEP. Check whether the RMEP is enabled to send CCMs.
3.Perform the following steps on the RMEP:
4.Run the display cfm remote-mep [ md md-name ma ma-name mep-id mep-id ] command to view the value of the CCM Receive field on the MEP.
5.Perform the following steps on the MEP:
6.Run the display this command in the interface view to check whether the local or remote interface is shut down. In the case of a sub-interface, you need to check whether a VLAN ID has been configured on the sub-interface and its peer sub-interface.
7.Check whether the physical link of the interface works improperly. That is, check whether the hardware such as the network cable or optical module is disconnected or loosely connected.
8.Collect alarm information and configuration information, and then contact technical support personnel.