EOAM-1AG/1/MISMERGE_active: MEP received a CCM with unexpected MEG ID. (MdIndex=[MdIndex], MaIndex=[MaIndex], MdName=[MdName], MaName=[MaName], MepId=[MepId])
An MD or MA name carried in a CCM sent by the RMEP was different from that specified on the MEP.
Parameter Name | Parameter Meaning |
---|---|
MdIndex |
Index of an MD table |
MaIndex |
Index of an MA table |
MdName |
Name of an MD |
MaName |
Name of an MA |
MepId |
ID of a MEP |
ifName |
Name of interface |
Vlan |
Vlan ID |
Direction |
Direction |
Level |
Level of MD |
An MD or MA name carried in a CCM sent by the RMEP was different from that specified on the MEP when the MEP and RMEP had the same MD level and service type in a MEG.
1. Run the display cfm mep [ md md-name [ ma ma-name [ mep-id mep-id ] ] ] command to view the value of the MD Name field on the MEP and RMEP that have the same service type and MD level. Check whether the MD names are the same.
2. Run the display cfm mep [ md md-name [ ma ma-name [ mep-id mep-id ] ] ] command to view the value of the MA Name field on the MEP and RMEP that have the same service type, MD level, and MD name. Check whether the MA names are the same.
3. Perform the following steps on the MEP:
4. Perform the following steps on the MEP:
5. Collect alarm information and configuration information, and then contact technical support personnel.