PIM/4/PIM_ROUTE_THRESHOLD_active

Message

PIM/4/PIM_ROUTE_THRESHOLD_active: The number of existed routing entries exceeded the global upper threshold. (LimitType=[LimitType], AddressFamily=[AddressFamily], CurrentCount=[CurrentCount], LimitCount=[LimitCount], ThresholdCount=[ThresholdCount], ReasonType=[ReasonType])

Description

The percentage ratio of created PIM entries on the device to the specified limit reached the alarm trigger threshold.

Parameters

Parameter Name Parameter Meaning

LimitType

Type of entry for which an entry number limit takes effect, which is one of the followings:

  • 1:PIM-SM (*, G) entry
  • 2:PIM-SM (S, G) entry
  • 3:PIM-DM (*, G) entry
  • 4:PIM-DM (S, G) entry

AddressFamily

Address family

CurrentCount

Number of created PIM entries on the device

LimitCount

Limit on the number of PIM entries on the device

ThresholdCount

Threshold at which the alarm is generated

ReasonType

Alarm cause, which is one of the followings:

  • Entries are changed.
  • The configuration is changed.

Possible Causes

  • Cause 1: Entry create
  • Cause 2: Configuration change

Procedure

  • Cause 1: Entry create

    1. Run the display multicast global outgoing-interface pim sm statistics command to check whether the alarm trigger threshold or the number limit is low.

    • If either the alarm trigger threshold or the number limit is low, go to Step 2.
    • If the alarm trigger threshold and the number limit are not low, go to Step 3.

    2. Run the multicast global limit command to modify the alarm trigger threshold or the number limit. Then, check whether the alarm is cleared.

    • If the alarm is cleared, go to Step 4.
    • If the alarm persists, go to Step 3.

    3. Collect alarm information and configuration information, and then contact technical support personnel.

    4. End.

  • Cause 2: Configuration change

    The same as Cause 1.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >