EOAM-Y1731/4/STATISTIC_active: The Y.1731 statistic value exceeded the upper limit value. (MdIndex=[MdIndex], MaIndex=[MaIndex], MepID=[MepID], Type=[Type], MAC=[MAC], Priority=[Priority], MdName=[MdName], MaName=[MaName], Value=[Value], UpperLimitThreshold=[UpperLimitThreshold], LowerLimitThreshold=[LowerLimitThreshold], ValueHigh=[ValueHigh], ValueLow=[ValueLow])
Parameter Name | Parameter Meaning |
---|---|
MdIndex |
Index of an MD table |
MaIndex |
Index of an MA table |
MepID |
MEG ID |
Type |
Alarm type |
MAC |
MAC address |
Priority |
Priority of performance measurement |
MdName |
Name of an MD |
MaName |
Name of an MA |
Value |
Statistic value |
UpperLimitThreshold |
Upper threshold |
LowerLimitThreshold |
Lower threshold |
ValueHigh |
32 most significant bits |
ValueLow |
32 least significant bits |
1. Rectify the fault based on the Type field value in the alarm information.
2. Run the display y1731 threshold-info onedelay-threshold md md-name ma ma-name mep-id mep-id [ 8021p 8021p-value ] command to view the values of UpperLimit and LowerLimit fields. Based on these values, determine whether the upper threshold for one-way frame delay is too small.
3. Run the display y1731 threshold-info twodelay-threshold md md-name ma ma-name mep-id mep-id [ 8021p 8021p-value ] command to view the values of UpperLimit and LowerLimit fields. Based on these values, determine whether the upper threshold for two-way frame delay is too small.
4. Run the display y1731 threshold-info onedelay-variation md md-name ma ma-name mep-id mep-id [ 8021p 8021p-value ] command to view the values of UpperLimit and LowerLimit fields. Based on these values, determine whether the upper threshold for one-way frame jitter is too small.
5. Run the display y1731 threshold-info twodelay-variation md md-name ma ma-name mep-id mep-id [ 8021p 8021p-value ] command to view the values of UpperLimit and LowerLimit fields. Based on these values, determine whether the upper threshold for two-way frame jitter is too small.
6. Run the display y1731 threshold-info singleloss-localratio md md-name ma ma-name mep-id mep-id [ 8021p 8021p-value ] command to view the values of UpperLimit and LowerLimit fields. Based on these values, determine whether the upper threshold for the near-end frame loss rate of single-ended frame loss is too small.
7. Run the display y1731 threshold-info singleloss-remoteratio md md-name ma ma-name mep-id mep-id [ 8021p 8021p-value ] command to view the values of UpperLimit and LowerLimit fields. Based on these values, determine whether the upper threshold for the far-end frame loss rate of single-ended frame loss is too small.
8. Run the display y1731 threshold-info dualloss-localratio md md-name ma ma-name mep-id mep-id command to view the values of UpperLimit and LowerLimit fields. Based on these values, determine whether the upper threshold for the near-end frame loss rate of dual-ended frame loss is too small.
9. Run the display y1731 threshold-info dualloss-localratio md md-name ma ma-name mep-id mep-id command to view the values of UpperLimit and LowerLimit fields. Based on these values, determine whether the upper threshold for the far-end frame loss rate of dual-ended frame loss is too small.
10. In the system view, run the display alarm active command to check whether the alarm is cleared. If no, go to 11.
11. Collect alarm information and configuration information, and then contact technical support personnel.
12. End.