AAA/4/STOP_ACCT_FAIL

Message

AAA/4/STOP_ACCT_FAIL: Failed to stop the normal accounting. (User=[user-name], AcctSessionID=[acct-session-id])

In VS mode, this log is supported only by the admin VS.

Description

Failed to stop common accounting.

Parameters

Parameter Name Parameter Meaning

user-name

Indicates the name of a user.

acct-session-id

Indicates the ID of the accounting session.

Possible Causes

Cause 1: The accounting server turned Down.

Cause 2: The device was disconnected from the accounting server.

Procedure

1. Check whether the accounting server works normally.

  • If not, contact the maintenance personnel of it.
  • If yes, go to 2.

2. Ping the accounting server from the device.

  • If the ping fails, check whether the physical connection is faulty or the route is reachable.
  • If the ping succeeds, go to 3.

3. Collect log information and configuration information, and then contact technical support personnel.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >