EOAM-1AG/1/UNEXPECTEDMEGLEVEL_active: MEP received a CCM with unexpected MEG level. (MdIndex=[MdIndex], MaIndex=[MaIndex], MdName=[MdName], MaName=[MaName], MepId=[MepId])
The MD level carried in a CCM sent by the RMEP was different from that specified on the MEP.
Parameter Name | Parameter Meaning |
---|---|
MdIndex |
Index of an MD table |
MaIndex |
Index of an MA table |
MdName |
Name of an MD |
MaName |
Name of an MA |
MepId |
ID of a MEP |
ifName |
Name of interface |
Vlan |
Vlan ID |
Direction |
Direction |
Level |
Level of MD |
The MD level carried in a CCM sent by the RMEP was different from that specified on the MEP.
1. Run the display cfm mep [ md md-name [ ma ma-name [ mep-id mep-id ] ] ] command on both the MEP and RMEP to view the value of the Level field. Check whether the MD levels are the same.
2. Perform the following steps on the MEP:
3. Collect alarm information and configuration information, and then contact technical support personnel.