EOAM-Y1731/4/VLAN_2DM_EXCEED_THRESHOLD_clear

Message

EOAM-Y1731/4/VLAN_2DM_EXCEED_THRESHOLD_clear: The result of two-way delay-measure is under the threshold. (MdIndex=[MdIndex], MaIndex=[MaIndex], RemoteMacAddress=[RemoteMacAddress], Timestamp=[Timestamp], DelayValue=[DelayValue], ThresholdValue=[ThresholdValue], DelayValueHigh=[DelayValueHigh], DelayValueLow=[DelayValueLow])

Parameters

Parameter Name Parameter Meaning

MdIndex

Index of the MD where a two-way frame delay alarm is generated

MaIndex

Index of the MA where a two-way frame delay alarm is generated

RemoteMacAddress

Source MAC address contained in the DMR frame received by the local end from the remote end

Timestamp

Timestamp indicating the time when a two-way frame delay alarm is generated

DelayValue

Delay when a two-way frame delay alarm is generated

ThresholdValue

An alarm threshold for two-way frame delay measurement

DelayValueHigh

32 most significant bits

DelayValueLow

32 least significant bits

Possible Causes

The device in VLAN networking was enabled with two-way frame delay measurement and was configured with an expected alarm threshold, the network delay fell below the alarm threshold and a two-way frame delay alarm had been generated.

Procedure

This alarm message is informational only, and no action is required.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic