DRIVER/3/VOLMONITORFAIL

Message

DRIVER/3/VOLMONITORFAIL: Slot [BoardSlotID] voltage monitor failed.

In VS mode, this log is supported only by the admin VS.

Description

The voltage sensor of the MonitorBus was faulty.

Parameters

Parameter Name Parameter Meaning

BoardSlotID

ID of the slot where the board with the MonitorBus is inserted

Possible Causes

The voltage sensor of the MonitorBus was faulty owning to a hardware fault.

Procedure

1. Check whether the log VOLMONITORRESUME (indicating that the voltage sensor of the MonitorBus recovered) is displayed.

  • If the log is displayed, go to Step 4. If the log is not displayed, go to Step 2.
  • If the fault persists and cannot be rectified, replace the board and check whether the log is displayed any longer.

2. If the log is not displayed any longer, go to Step 4. If the log is still displayed, go to Step 3.

3. Collect the alarm information, log information, and configuration information, and contact technical support engineers.

4. End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >