DEFEND/4/hwBaseSecurityTtlExpiredLoop_active

Message

DEFEND/4/hwBaseSecurityTtlExpiredLoop_active: TTL-expired loop detect alarmed, a loop may occur on the slot. (CHASSISID=[CHASSISID], SLOTID=[SLOTID], LASTRATELOW=[LASTRATELOW], LASTRATEHIGH=[LASTRATEHIGH], CURRENTRATELOW=[CURRENTRATELOW], CURRENTRATEHIGH=[CURRENTRATEHIGH], INTERVAL=[INTERVAL], THRESHOLD=[THRESHOLD])

In VS mode, this log is supported only by the admin VS.

Description

A TTL timeout loop detection alarm was generated, indicating that a loop occurred in the slot.

Parameters

Parameter Name Parameter Meaning

CHASSISID

Chassis ID.

SLOTID

Slot ID.

LASTRATELOW

Rightmost 32 bits collected during the previous period.

LASTRATEHIGH

Leftmost 32 bits collected during the previous period.

CURRENTRATELOW

Rightmost 32 bits collected during the current period.

CURRENTRATEHIGH

Leftmost 32 bits collected during the current period.

INTERVAL

Interval at which alarms are collected.

THRESHOLD

Alarm threshold.

Possible Causes

After the TTL-timeout-based loop detection alarm function is enabled on a board, the board periodically checks statistics about the TTL timeout packets dropped using CAR. When the number of the dropped TTL timeout bytes exceeds 1000 and the percentage of the dropped TTL timeout bytes during this period in that during the previous period is lower than the configured threshold, a routing loop occurs on the board, and the device generates an alarm.(The default interval is 60 seconds and the default threshold percentage is 10%. Both of them can be configured.)

Procedure

1. Check routing entries to determine whether a routing loop exists.

2. Collect trap, log, and configuration information, and contact technical support personnel.

3. End.