BFD/3/hwBfdSessReachTotalLimit_active

Message

BFD/3/hwBfdSessReachTotalLimit_active: The number of BFD sessions on all IO boards has reached the upper limit, and new sessions cannot be created. (TotalSessionLimit=[TotalSessionLimit])

In VS mode, this log is supported only by the admin VS.

Description

The number of BFD sessions reached the upper limit.

Parameters

Parameter Name Parameter Meaning

TotalSessionLimit

Maximum number of BFD sessions.

Possible Causes

The number of the BFD sessions on the device exceeded the upper limit.

Procedure

1.On the NMS, check whether the number of BFD sessions reaches the upper limit. Delete redundant BFD sessions and check whether the alarm is cleared. 2.If the alarm persists, contact Huawei technical support personnel.