BIER/2/hwBierPrefixBfridConflict_active: In the same BIER sub-domain, BFR-ID configuration conflicts exist. (AddressFamily=[AddressFamily], SubdomainID=[SubdomainID], ConflictType=[ConflictType], ConflictBFRID=[ConflictBFRID], ConflictPrefix=[ConflictPrefix], ConflictState=[ConflictState], AdvertiserCurrent=[AdvertiserCurrent], AdvertiserNew=[AdvertiserNew], BierPrefixCurrent =[BierPrefixCurrent], BierPrefixNew=[BierPrefixNew], BFRIDCurrent=[BFRIDCurrent], BFRIDNew=[BFRIDNew])
Parameter Name | Parameter Meaning |
---|---|
AddressFamily |
Address family. |
SubdomainID |
BIER sub-domain. |
ConflictType |
Conflict type. |
ConflictBFRID |
Conflicting BFR-ID. |
ConflictPrefix |
Conflicting prefix. |
ConflictState |
Conflict state. |
AdvertiserCurrent |
Current advertiser. |
AdvertiserNew |
New advertiser. |
BierPrefixCurrent |
BIER prefix of the current advertiser. |
BierPrefixNew |
BIER prefix of the new advertiser. |
BFRIDCurrent |
BFR-ID of the current advertiser. |
BFRIDNew |
BFR-ID of the new advertiser. |
1. In the BIER sub-domain view of each device, run the display this command to check the BFR-ID value configured on each device and check whether the same BFR-ID exists.
2. Collect alarm and configuration information and contact technical support engineers.
3. End.