DEVM/1/hwBoardFail_active: The board partially failed.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType],EntityTrapFaultID=132100,Reason=Failed to detect the slot ID of the board.)
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
EntityPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalName |
Indicates the name of the physical entity. |
EntityType |
Indicates the type of the physical entity. The value can be one of the following: -1: mpu(1) -2: lpu(2) -3: sfu(3) -4: pic(4) -5: cfcard(5) -6: ofc(6) -7: board(7) -255: other(255) |
EntityTrapFaultID |
Indicates the error code. |
Reason |
Indicates the description of the cause of the trap. |
1. If the board is neither reset nor powered off, and services on the board are normal, go to Step 4.
2. Power off the faulty board and then power it on again.
3. If the board cannot be registered or the alarm persists after the board is registered, go to Step 4.
4. Collect trap, log, and configuration information, and contact technical support.
5. End.