DEVM/1/hwBoardFail_active-132103

Message

DEVM/1/hwBoardFail_active: The board partially failed.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType],EntityTrapFaultID=132103,Reason=The batteries on the MPU failed.)

In VS mode, this log is supported only by the admin VS.

Description

The board experienced a partial failure.

Parameters

Parameter Name Parameter Meaning

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalName

Indicates the name of the physical entity.

EntityType

Indicates the type of the physical entity. The value can be one of the following:

-1: mpu(1)

-2: lpu(2)

-3: sfu(3)

-4: pic(4)

-5: cfcard(5)

-6: ofc(6)

-7: board(7)

-255: other(255)

EntityTrapFaultID

Indicates the error code.

Reason

Indicates the description of the cause of the trap.

Possible Causes

The batteries are invalid.

Procedure

1. If an installed board has no services on it, check whether the board is properly installed, pins have bent, and the board connectors are faulty.

2. If the board is not securely installed, install it securely.

3. If the pins on the backplane have bent, do not install a new board into the improper slot. Contact technical support.

4. If only the board connectors are found to be faulty, replace the board.

5. If services on the board are normal, collect trap, log, and configuration information, and contact technical support.

6. End.

Copyright © Huawei Technologies Co., Ltd.