DEVM/1/hwBoardFail_active: The board partially failed.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType],EntityTrapFaultID=132108,Reason=The clock signal of the clock board is abnormal)
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
EntityPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalName |
Indicates the name of the physical entity. |
EntityType |
Indicates the type of the physical entity. The value can be one of the following: -1: mpu(1) -2: lpu(2) -3: sfu(3) -4: pic(4) -5: cfcard(5) -6: ofc(6) -7: board(7) -255: other(255) |
EntityTrapFaultID |
Indicates the error code. |
Reason |
Indicates the description of the cause of the trap. |
1. Check whether the two main control boards are securely installed. If not, install the them securely.
2. If an installed board has no services on it, check whether the board is properly installed, pins have bent, and the board connectors are faulty.
3. If the board is not securely installed, install it securely.
4. If the pins on the backplane have bent, do not install a new board into the improper slot. Contact technical support.
5. If only the board connectors are found to be faulty, replace the board.
6. If service have run on the faulty board but the alarm persists, collect trap, log, and configuration information, and contact technical support.
7. End.