DEVM/1/hwBoardFail_active-132122

Message

DEVM/1/hwBoardFail_active: The board partially failed.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType],EntityTrapFaultID=132122,Reason=The CFcard of the MPU board is abnormal.)

In VS mode, this log is supported only by the admin VS.

Description

The board experienced a partial failure.

Parameters

Parameter Name Parameter Meaning

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalName

Indicates the name of the physical entity.

EntityType

Indicates the type of the physical entity. The value can be one of the following:

-1: mpu(1)

-2: lpu(2)

-3: sfu(3)

-4: pic(4)

-5: cfcard(5)

-6: ofc(6)

-7: board(7)

-255: other(255)

EntityTrapFaultID

Indicates the error code.

Reason

Indicates the description of the cause of the trap.

Possible Causes

The CFcard of the MPU board is abnormal.

Procedure

1. Remove and install the CF card and restart the board where the CF card resides as the standby main control board.

2. If the board is not registered, replace the faulty CF card and then restart the board.

3. If the board fails to be registered, replace the board.

4. Replace the faulty CF card and then restart the board. If the board is not registered or the alarm persists after the board is registered, replace the board where the faulty CF card resides.

5. If the alarm persists, collect trap, log, and configuration information, and contact technical support.

6. End.