DEVM/1/hwBoardFail_active: The board partially failed.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType],EntityTrapFaultID=132122,Reason=The CFcard of the MPU board is abnormal.)
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
EntityPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalName |
Indicates the name of the physical entity. |
EntityType |
Indicates the type of the physical entity. The value can be one of the following: -1: mpu(1) -2: lpu(2) -3: sfu(3) -4: pic(4) -5: cfcard(5) -6: ofc(6) -7: board(7) -255: other(255) |
EntityTrapFaultID |
Indicates the error code. |
Reason |
Indicates the description of the cause of the trap. |
1. Remove and install the CF card and restart the board where the CF card resides as the standby main control board.
2. If the board is not registered, replace the faulty CF card and then restart the board.
3. If the board fails to be registered, replace the board.
4. Replace the faulty CF card and then restart the board. If the board is not registered or the alarm persists after the board is registered, replace the board where the faulty CF card resides.
5. If the alarm persists, collect trap, log, and configuration information, and contact technical support.
6. End.