DEVM/1/hwBoardFail_active-132140

Message

DEVM/1/hwBoardFail_active: The board partially failed.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType],EntityTrapFaultID=132140,Reason=The subcard voltage exceeded the upper limit of the critical threshold.)

This log is supported only on NetEngine 8000 F1A.

In VS mode, this log is supported only by the admin VS.

Description

The board experienced a partial failure.

Parameters

Parameter Name Parameter Meaning

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalName

Indicates the name of the physical entity.

EntityType

Indicates the type of the physical entity. The value can be one of the following:

-1: mpu(1)

-2: lpu(2)

-3: sfu(3)

-4: pic(4)

-5: cfcard(5)

-6: ofc(6)

-7: board(7)

-255: other(255)

EntityTrapFaultID

Indicates the error code.

Reason

Indicates the description of the cause of the trap.

Possible Causes

The voltage of the subcard exceeded the upper threshold.

Procedure

1. Run the display voltage lpu slot slot-id command in the user view to check the voltage information about the subcards. If the fault cannot be rectified within a short period of time, replace the subcard.

2. If the alarm persists, collect trap, log, and configuration information, and contact technical support.

3. End.