DEVM/1/hwBoardFail_active-132425

Message

DEVM/1/hwBoardFail_active: The board partially failed.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType],EntityTrapFaultID=132425,The FPGA1 logic of the board is abnormal)

In VS mode, this log is supported only by the admin VS.

Description

The board experienced a partial failure.

Parameters

Parameter Name Parameter Meaning

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalName

Indicates the name of the physical entity.

EntityType

Indicates the type of the physical entity. The value can be one of the following:

-1: mpu(1)

-2: lpu(2)

-3: sfu(3)

-4: pic(4)

-5: cfcard(5)

-6: ofc(6)

-7: board(7)

-255: other(255)

EntityTrapFaultID

Indicates the error code.

Reason

Indicates the description of the cause of the trap.

Possible Causes

The FPGA1 logic of the board is abnormal.

Procedure

1. If the board is not reset or powered off and services are running properly, collect alarm, log, and configuration information and contact technical support. Otherwise, go to Step 2.

2. Power off the faulty board and then power it on again.

3. If the board cannot be registered or the alarm persists after the board is registered, replace the faulty board.

4. If the alarm persists, collect alarm, log, and configuration information and contact technical support.

5. End.