DEVM/1/hwBoardInvalid_active-132614

Message

DEVM/1/hwBoardInvalid_active: The board totally failed. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType], EntityTrapFaultID=132614, Reason=The EPLD logic of the board failed.)

In VS mode, this log is supported only by the admin VS.

Description

The overall function of the board does not take effect.

Parameters

Parameter Name Parameter Meaning

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalName

Indicates the name of the entity such as a chassis.

EntityType

Indicates the type of the physical entity. The value can be one of the following:

  • 1: mpu(1)
  • 2: lpu(2)
  • 3: sfu(3)
  • 4: pic(4)
  • 5: cfcard(5)
  • 6: ofc(6)
  • 7: npu(7)

EntityTrapFaultID

Indicates the error code.

Reason

Indicates the description of the cause of the trap.

Possible Causes

The EPLD logic of the board failed.

Procedure

1. Go to Step 2 if the faulty board is not the main control board.

2. If the faulty board is registered, run the EPlD upgrade command in the user view: upgrade mpu/lpu/sfu slotid startup firmware. Then, go to Step 4.

3. If the faulty board is not registered, power off and then power on the faulty board.

4. If the faulty board cannot be registered or the fault persists after the board is registered, replace the faulty board.

5. If the alarm persists, collect alarm, log, and configuration information and contact technical support engineers.

6. End.