DEVM/1/hwBoardInvalid_active: The board totally failed. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType], EntityTrapFaultID=132619, Reason=The master or slave ACT signal of the MPU board is abnormal.)
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
EntityPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalName |
Indicates the name of the entity such as a chassis. |
EntityType |
Indicates the type of the physical entity. The value can be one of the following:
|
EntityTrapFaultID |
Indicates the error code. |
Reason |
Indicates the description of the cause of the trap. |
1. Check whether other boards have low-power-related alarms or power-related alarms. If so, handle these alarms first.
2. Remove and reinstall the current standby main control board and check whether the standby main control board is securely installed, whether any bent pins exist, and whether the connectors of the standby main control board are normal. Then, go to Step 4.
3. If the device is reset, remove the other main control board and check whether the main control board is securely installed, whether any bent pins exist, and whether the connectors of the main control board are normal. Then, go to Step 4.
4. If the board is not securely installed, install it securely.
5. If the backplane has bent pins, avoid installing a new board into the faulty slot. Contact technical support.
6. If only the connectors of the board are found to be faulty, replace the board and go to Step 8.
7. If the standby main control board is still not registered or the alarm persists, contact technical support.
8. End.