DEVM/1/hwBoardInvalid_active-132670

Message

DEVM/1/hwBoardInvalid_active: The board totally failed. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType], EntityTrapFaultID=132670, Reason=The user-input supply power of the board is insufficient.)

In VS mode, this log is supported only by the admin VS.

Description

The overall function of the board does not take effect.

Parameters

Parameter Name Parameter Meaning

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalName

Indicates the name of the entity such as a chassis.

EntityType

Indicates the type of the physical entity. The value can be one of the following:

  • 1: mpu(1)
  • 2: lpu(2)
  • 3: sfu(3)
  • 4: pic(4)
  • 5: cfcard(5)
  • 6: ofc(6)
  • 7: npu(7)

EntityTrapFaultID

Indicates the error code.

Reason

Indicates the description of the cause of the trap.

Possible Causes

The user-input supply power of the board is insufficient.

Procedure

1. Check whether the device is equipped with sufficient power modules.

  • If power modules are sufficient, go to Step 2.
  • If power modules are not sufficient, go to Step 3.

2. Check whether the maximum power consumption allowed is too small.

  • If the maximum power consumption allowed is too small, change it to a proper value and then go to Step 4.
  • If the maximum power consumption allowed is not too small, go to Step 5.

3. Install extra power modules.

4. Check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 6.
  • If the alarm persists, go to Step 5.

5. Collect trap, log, and configuration information, and contact technical support.

6. End.