DEVM/1/hwBoardInvalid_active: The board totally failed. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType], EntityTrapFaultID=132676, Reason=Power supply is insufficient to improve the fan power.)
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
EntityPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalName |
Indicates the name of the entity such as a chassis. |
EntityType |
Indicates the type of the physical entity. The value can be one of the following:
|
EntityTrapFaultID |
Indicates the error code. |
Reason |
Indicates the description of the cause of the trap. |
1. Check whether the device is equipped with sufficient power modules.
2. Install extra power modules.Check whether the alarm is cleared.
3. Collect trap, log, and configuration information, and contact technical support.
4. End.