DEVM/2/hwBrdTempFatalAlarm_active: The board temperature exceeded the fatal alarm threshold. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName],EntityThresholdType=[EntityThresholdType], EntityThresholdCritical=[EntityThresholdCritical], EntityThresholdCurrent=[EntityThresholdCurrent], EntityTrapFaultID=143872, Reason=The board temperature was extremely high.)
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
EntityPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalName |
Indicates the name of the physical entity. |
EntityThresholdType |
The abnormal type for temperature: 1: hige. 2: low. |
EntityThresholdCritical |
The critical alarm threshold for critical alarm. |
EntityThresholdCurrent |
The current value that been measured. |
EntityTrapFaultID |
To describe the fault id of trap. |
Reason |
Indicates the description of the cause of the trap. |
1. Check if there are idle slots without filler panels on the device. If there are idle slots without filler panels, install filler panels to cover these slots.
2. Check if the filter screen of the fan module is clogged. If the filter screen is clogged, clean the filter screen.
3. Check the ambient temperature. If the ambient temperature is too high, reduce the temperature to a normal level.
4. Check if the fan module is faulty. If there is a fault on the fan module, rectify the fault first.
5. If the ambient temperature is normal but the alarm is still reported, the possible cause is that the module temperature is too high. In this case, collect the information about alarms, logs, and configurations, and then contact technical support personnel.
6. End.