L2VPN/3/hwCCCVcDown_active: The status of the CCC VC turned DOWN. (CccName=[CccName], InterfaceIndex=[InterfaceIndex], InterfaceIndex=[InterfaceIndex2], HWL2VpnStateChangeReason=[HWL2VpnStateChangeReason], InterfaceName=[InterfaceName])
Parameter Name | Parameter Meaning |
---|---|
CccName |
Indicates the name of the CCC connection. |
InterfaceIndex |
Indicates the index of the AC interface that connects to the first CE. |
InterfaceIndex2 |
Indicates the index of the AC interface that connects to the second CE. |
HWL2VpnStateChangeReason |
Indicates the cause of the VC status change. |
InterfaceName |
Indicates the AC interface name. |
Collect alarm information and configuration information, and then contact technical support personnel.
1. Confirm that whether the CCC is need to be deleted.
2. Recreate the CCC connection. Then, check whether the alarm is cleared.
3. Collect alarm information and configuration information, and then contact technical support personnel.
4. End.
1. Check whether the current configuration is the same as the original configuration. For example, check whether MPLS is enabled globally, or whether MPLS is enabled on the CCC outbound interface.
2. Restore the original configuration. Then, check whether the alarm is cleared.
3. Run the display vll ccc ccc-name command to check the status of the incoming and outgoing interfaces of the CCC VC.
4. View the cause why the interface is Down and restore the interface to the Up status. Then, check whether the alarm is cleared.
5. Run the display ip routing-table command to check whether the IP address is reachable.
6. Run the display ip interface brief command to check whether there are addresses that are in the same segment with the IP address.
7. Enter the view of the outbound interface and reconfigure an IP address in consistent with the original configuration. Then, check whether the alarm is cleared.
8. Collect alarm information and configuration information, and then contact technical support personnel.
9. End.
1. Check whether the current configuration is the same as the original configuration.
2. Restore the original configuration and check whether the alarm is cleared.
3. Run the display vll ccc ccc-name command to check the inbound and outbound interface status of the CCC.
4. Configure the interfaces to go Up and check whether the alarm is cleared.
5. Run the display ip routing-table command to check whether the IP address is reachable.
6. Run the display ip interface brief command to check whether IP addresses that are on the same network segment as this IP address exist.
7. Enter the outbound interface view, re-configure the IP address, and check whether the alarm is cleared.
8. Contact technical support personnel.
9. End.
Collect alarm information and configuration information, and then contact technical support personnel.