SYSTEM/1/hwCPUUtilizationRisingAlarm_active: The CPU usage exceeded the pre-set overload threshold. (TrapSeverity=[TrapSeverity],ProbableCause=[ProbableCause],EventType=[EventType],PhysicalIndex=[PhysicalIndex],PhysicalName=[PhysicalName],RelativeResource=[RelativeResource],UsageType=[UsageType],SubIndex=[SubIndex],CpuUsage=[CpuUsage],Unit=[Unit],CpuUsageThreshold=[CpuUsageThreshold])
In VS mode, this log is supported only by the admin VS.
Continuously sample CPU utilization. In a sampling period, if the CPU usage sampled each time is greater than the overload threshold, this alarm is generated. The default sampling interval is 8 minutes.
Parameter Name | Parameter Meaning |
---|---|
SubIndex |
Entity sub-index. |
ProbableCause |
Alarm cause. |
TrapSeverity |
Alarm severity. |
EventType |
Alarm type. |
PhysicalIndex |
Index of a physical entity. |
PhysicalName |
Entity name. |
RelativeResource |
Name of the related resource. |
UsageType |
Overload type. |
CpuUsage |
CPU usage. |
Unit |
Unit. |
CpuUsageThreshold |
CPU overload threshold. |
1. Run the display cpu-usage [configuration | service] [slave | slot slot-id] command to check the CPU usage and overload threshold.
2. Reduce unnecessary services and configurations to reduce the CPU usage. Then, check whether the alarm is cleared.
3. Run the set cpu-usage threshold threshold-value [ restore ] [ interval ] [ slave | slot ] command to adjust the overload threshold. Then, check whether the alarm is cleared.
4. Collect alarm and configuration information and contact technical support.
Collect alarm and configuration information and contact technical support.
Collect alarm, log, and configuration information and contact Huawei technical support.