PIC/1/hwCardFail_active: The card failed partially. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType], EntityTrapFaultID=132140, Reason=The voltage exceeds the upper alarm threshold.)
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
EntityPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalName |
Indicates the name of the physical entity. |
EntityType |
Indicates the type of the physical entity. |
EntityTrapFaultID |
Indicates the error code. |
Reason |
Indicates the description of the cause of the trap. |
1. If the power module fails, first rectify the fault.
2. Run the display voltage slot slot-id command in the user view to check whether the actual voltage exceeds the upper fatal threshold.
3. If the actual voltage exceeds the upper fatal threshold, collect the information about alarms, logs, and configurations, and then contact technical support personnel.