PIC/1/hwCardFail_active-132140

Message

PIC/1/hwCardFail_active: The card failed partially. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType], EntityTrapFaultID=132140, Reason=The voltage exceeds the upper alarm threshold.)

In VS mode, this log is supported only by the admin VS.

Description

The subcard experienced a partial failure.

Parameters

Parameter Name Parameter Meaning

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalName

Indicates the name of the physical entity.

EntityType

Indicates the type of the physical entity.

EntityTrapFaultID

Indicates the error code.

Reason

Indicates the description of the cause of the trap.

Possible Causes

The voltage exceeds the upper alarm threshold.

Procedure

1. If the power module fails, first rectify the fault.

2. Run the display voltage slot slot-id command in the user view to check whether the actual voltage exceeds the upper fatal threshold.

3. If the actual voltage exceeds the upper fatal threshold, collect the information about alarms, logs, and configurations, and then contact technical support personnel.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.