PIC/1/hwCardInvalid_active: The card failed completely. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType], EntityTrapFaultID=135430, ReasonDescription=The heartbeat of the subcard was faulty.)
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
EntityPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalName |
Indicates the name of the physical entity. |
EntityType |
Indicates the type of the physical entity. |
EntityTrapFaultID |
Indicates the error code. |
ReasonDescription |
Indicates the description of the cause of the trap. |
1.If the motherboard on which the subcard resides does not support FPIC, go to Step 5.
2.If the motherboard on which the subcard resides resets, no action is required.
3.Power off the subcard and then power it on again.
4.If the subcard cannot be registered or the alarm persists after the subcard is registered, replace the subcard.
5.If the motherboard supports only one subcard, power off the motherboard and then power it on again.
6.If the motherboard does not support FPIC, and the motherboard cannot be registered or the alarm persists after the motherboard is registered, replace the motherboard.
7.If the motherboard supports FPIC, and the motherboard cannot be registered or the alarm persists after the motherboard is registered, replace the subcard. If the fault persists, replace the motherboard.
8.Collect the information about alarms, logs, and configurations, and then contact technical support personnel.
9.End.