DEVM/1/hwCopperPolarityError_active

Message

DEVM/1/hwCopperPolarityError_active: Copper polarity error alarm.(hwPhysicalPortIfIndex=[hwPhysicalPortIfIndex],InterfaceName=[hwPhysicalPortName])

Description

The bipolar violation occurred on an electrical interface.

Parameters

Parameter Name Parameter Meaning

hwPhysicalPortIfIndex

Index of physical port.

hwPhysicalPortName

Name of physical port.

Possible Causes

The bipolar violation occurred on STPs/network cables.

Procedure

1. Replace the faulty STPs/network cables with normal STPs/network cables.

  • If the alarm is cleared, go to end.
  • If the alarm is not cleared, go to Step 2.

2. Collect alarm information, log information and configuration information, and then contact technical support personnel.