EMDI/4/hwEmdiBierOutRtpLrOverThreshold_active

Message

EMDI/4/hwEmdiBierOutRtpLrOverThreshold_active: The outbound packet loss rate of the channel exceeds the threshold. (ChannelSourceAddress=[hwEmdiChannelSourceAddress], ChannelGroupAddress=[hwEmdiChannelGroupAddress], VpnLabel=[hwEmdiVpnLabel], BfirId=[hwEmdiBfirId], SubDomain=[hwEmdiSubDomain], Bsl=[hwEmdiBsl], SI=[hwEmdiSi], RtpLrThreshold=[hwEmdiRtpLrThreshold], RtpLr=[hwEmdiRtpLrValue], Slot=[hwEmdiChannelSlot], Interface=[hwEmdiChannelInterface], Token=[hwEmdiToken])

This log is supported only on NetEngine 8000 F1A.

Description

The outbound RTP-LR of the channel exceeds the threshold.

Parameters

Parameter Name Parameter Meaning

hwEmdiChannelSourceAddress

Channel source address.

hwEmdiChannelGroupAddress

Channel group address.

hwEmdiVpnLabel

VPN label.

hwEmdiBfirId

Bit forwarding ingress router id.

hwEmdiSubDomain

Sub domain.

hwEmdiBsl

BitString length.

hwEmdiSi

Set identifier.

hwEmdiRtpLrThreshold

Current packet loss rate threshold of a channel.

hwEmdiRtpLrValue

Current packet loss rate value.

hwEmdiChannelSlot

Slot ID.

hwEmdiChannelInterface

Interface Name.

hwEmdiToken

Multicast leaf token.

Possible Causes

The outbound packet loss rate of the bier channel exceeds the threshold.

Procedure

1.According to the Bier eMDI statistical information to confirm the fault equipment. (Bier eMDI does not differentiate upstream and downstream traffic. Bier eMDI needs to globally analyze fault points on the entire network based on information about each detection point.)

2.Replace optical modules or optical fibers of faulty equipment. Then check whether the trap is cleared.

  • If the trap is cleared, go to Step 4.
  • If the trap persists, go to Step 3.

3.Collect trap, log, and configuration information, and then contact technical support personnel.

4.End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
Next topic >