EMDI/4/hwEmdiBierRtpLrOverThreshold_active: Channel packet loss rate exceeds the threshold. (ChannelSourceAddress=[hwEmdiChannelSourceAddress], ChannelGroupAddress=[hwEmdiChannelGroupAddress], VpnLabel=[hwEmdiVpnLabel], BfirId=[hwEmdiBfirId], SubDomain=[hwEmdiSubDomain], Bsl=[hwEmdiBsl], SI=[hwEmdiSi], RtpLrThreshold=[hwEmdiRtpLrThreshold], RtpLr=[hwEmdiRtpLrValue])
Parameter Name | Parameter Meaning |
---|---|
hwEmdiChannelSourceAddress |
Channel source address. |
hwEmdiChannelGroupAddress |
Channel group address. |
hwEmdiVpnLabel |
VPN label. |
hwEmdiBfirId |
Bit forwarding ingress router id. |
hwEmdiSubDomain |
Sub domain. |
hwEmdiBsl |
BitString length. |
hwEmdiSi |
Set identifier. |
hwEmdiRtpLrThreshold |
Current packet loss rate threshold of a channel. |
hwEmdiRtpLrValue |
Current packet loss rate value. |
1.According to the Bier eMDI statistical information to confirm the fault equipment. (Bier eMDI does not differentiate upstream and downstream traffic. Bier eMDI needs to globally analyze fault points on the entire network based on information about each detection point.)
2.Replace optical modules or optical fibers of faulty equipment. Then check whether the trap is cleared.
3.Collect trap, log, and configuration information, and then contact technical support personnel.
4.End.