DEVM/2/hwEntityCheckFail_active-68142

Message

DEVM/2/hwEntityCheckFail_active: Physical is detected failed. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=68142, BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=Power_BackPlane is failed, the number of pm on two plane is different)

In VS mode, this log is supported only by the admin VS.

Description

Physical entity is detected failed.

Parameters

Parameter Name Parameter Meaning

BaseTrapSeverity

indicates the severity level of the trap reported to the NMS.

BaseTrapProbableCause

Indicates the possible cause of the trap.

BaseTrapEventType

Indicates the trap type.

EntityPhysicalIndex

Physical index. The physical index varies with the chassis ID.

EntPhysicalContainedIn

Indicates the parent index.

EntPhysicalName

Indicates the name of the entity such as a chassis.

RelativeResource

Indicates the name of the part related to the trap.

ReasonDescription

Indicates the description of the possible cause.

Possible Causes

The two power supply planes have different number of PMs.

Procedure

1. Check the number of PMs installed on each power supply plane and install more PMs on the plane with less PMs to ensure that the two planes have the same number of PMs. Then check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 3.
  • If the alarm persists, go to Step 2.

2. Collect alarm, log, and configuration information, and contact technical support personnel.

3. End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >