DEVM/2/hwEntityCheckFail_active: Physical is detected failed. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=68142, BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=Power_BackPlane is failed, the number of pm on two plane is different)
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
BaseTrapSeverity |
indicates the severity level of the trap reported to the NMS. |
BaseTrapProbableCause |
Indicates the possible cause of the trap. |
BaseTrapEventType |
Indicates the trap type. |
EntityPhysicalIndex |
Physical index. The physical index varies with the chassis ID. |
EntPhysicalContainedIn |
Indicates the parent index. |
EntPhysicalName |
Indicates the name of the entity such as a chassis. |
RelativeResource |
Indicates the name of the part related to the trap. |
ReasonDescription |
Indicates the description of the possible cause. |
1. Check the number of PMs installed on each power supply plane and install more PMs on the plane with less PMs to ensure that the two planes have the same number of PMs. Then check whether the alarm is cleared.
2. Collect alarm, log, and configuration information, and contact technical support personnel.
3. End.