DEVM/2/hwEntityCheckFail_active: Physical entity is detected failed. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=69636, BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntPhysicalContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=MPU <slotid>%s is failed, the chassis ID conflict.)
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
BaseTrapSeverity |
indicates the severity level of the trap reported to the NMS. |
BaseTrapProbableCause |
Indicates the possible cause of the trap. |
BaseTrapEventType |
Indicates the trap type. |
EntityPhysicalIndex |
Physical index. The physical index varies with the chassis ID. |
EntPhysicalContainedIn |
Indicates the parent index. |
EntPhysicalName |
Indicates the name of the entity such as a chassis. |
RelativeResource |
Indicates the name of the part related to the trap. |
ReasonDescription |
Indicates the description of the possible cause. |
1. Check alarm information and locate the chassis with a conflicting ID.
2. Run the set [ chassis chassis ] chassis-id chassis-id command to set the ID of the chassis. Check whether the trap is cleared.
3. Collect trap information, log information, and configuration information, and then contact technical support personnel.
4. End.