DEVM/2/hwEntityCheckFail_clear

Message

DEVM/2/hwEntityCheckFail_clear: Physical entity is detected resumed from failure.(BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=[BaseTrapProbableCause], BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntPhysicalContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=[ReasonDescription])

In VS mode, this log is supported only by the admin VS.

Parameters

Parameter Name Parameter Meaning

BaseTrapSeverity

indicates the severity level of the trap reported to the NMS.

BaseTrapProbableCause

Indicates the possible cause of the trap.

BaseTrapEventType

Indicates the trap type.

EntityPhysicalIndex

Physical index. The physical index varies with the chassis ID.

EntPhysicalContainedIn

Indicates the parent index.

EntPhysicalName

Indicates the name of the entity such as a chassis.

RelativeResource

Indicates the name of the part related to the trap.

ReasonDescription

Indicates the description of the possible cause.

Possible Causes

  • Cause 1:Chassis IDs conflicted Resumed.
  • Cause 2:Failed to detect the MPU confliction Resumed.
  • Cause 68142:The two power supply planes had the same number of PMs.
  • Cause 68149:Traffic forwarding on the half chassis of a CCC is enabled.
  • Cause 68150:The conflict of optical fiber lengths of a clc is cleared.
  • Cause 68151:The SFU in ccc/slot number supports traffic forwarding in current fiber type.
  • Cause 68152:The fabric system is normal.
  • Cause 68159:The fault where the board type of the local chassis did not match that of the peer chassis was rectified.
  • Cause 68173:The fiber length in 40G .chassis is set.
  • Cause 68174:The number of tm resources is less than 90% of the total tm resources.
  • Cause 68186:Optical fibers on a clc have the same length.
  • Cause 69500:Fans and PEMs in the chassis match.
  • Cause 69636:Chassis IDs conflicted resumed.
  • Cause 69637:MPU confliction detection recovered.
  • Cause 69638:All the used logical positions of the optical module area are activated, or, all the optical modules are pulled out in inactive area.
  • Cause 69639:When the rollback time expires, secure boot is enabled.
  • Cause 69640:enable secure boot successfully.
  • Cause 69641:The management network is normal.
  • Cause 69642:One of the two installed ICUs on the CCC is removed.

Procedure

  • Cause 1:Chassis IDs conflicted Resumed.

    This trap message is informational only, and no action is required.

  • Cause 2:Failed to detect the MPU confliction Resumed.

    This trap message is informational only, and no action is required.

  • Cause 68142:The two power supply planes had the same number of PMs.

    This trap message is informational only, and no action is required.

  • Cause 68149:Traffic forwarding on the half chassis of a CCC is enabled.

    This trap message is informational only, and no action is required.

  • Cause 68150:The conflict of optical fiber lengths of a clc is cleared.

    This trap message is informational only, and no action is required.

  • Cause 68151:The SFU in ccc/slot number supports traffic forwarding in current fiber type.

    This trap message is informational only, and no action is required.

  • Cause 68152:The fabric system is normal.

    This trap message is informational only, and no action is required.

  • Cause 68159:The fault where the board type of the local chassis did not match that of the peer chassis was rectified.

    This trap message is informational only, and no action is required.

  • Cause 68173:The fiber length in 40G .chassis is set.

    This trap message is informational only, and no action is required.

  • Cause 68174:The number of tm resources is less than 90% of the total tm resources.

    This trap message is informational only, and no action is required.

  • Cause 68186:Optical fibers on a clc have the same length.

    This trap message is informational only, and no action is required.

  • Cause 69500:Fans and PEMs in the chassis match.

    This trap message is informational only, and no action is required.

  • Cause 69636:Chassis IDs conflicted resumed.

    This trap message is informational only, and no action is required.

  • Cause 69637:MPU confliction detection recovered.

    This trap message is informational only, and no action is required.

  • Cause 69638:All the used logical positions of the optical module area are activated, or, all the optical modules are pulled out in inactive area.

    This trap message is informational only, and no action is required.

  • Cause 69639:When the rollback time expires, secure boot is enabled.

    Information is normal, no action is required.

  • Cause 69640:enable secure boot successfully.

    This trap message is informational only, and no action is required.

  • Cause 69641:The management network is normal.

    This trap message is informational only,and no action is required.

  • Cause 69642:One of the two installed ICUs on the CCC is removed.

    Information is normal, no action is required.

Copyright © Huawei Technologies Co., Ltd.