DEVM/1/hwEntityInvalid_active-67618

Message

DEVM/1/hwEntityInvalid_active: Physical entity failed. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=[67618], BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=The input voltage of a power module was below a rated range.)

In VS mode, this log is supported only by the admin VS.

Description

Physical entity failed.

Parameters

Parameter Name Parameter Meaning

BaseTrapSeverity

To describe the level of trap.

ProbableCause

To describe the probable cause of trap.

BaseTrapEventType

To describe the type of trap.

EntityPhysicalIndex

The index of the physical entity.

EntContainedIn

The value of entPhysicalIndex for the physical entity.

EntPhysicalName

The textual name of the physical entity.

RelativeResource

This object may contain a key word to indicate the relative resource of an entity.

ReasonDescription

To describe the reason of trap in DisplayString style.

Possible Causes

The input voltage of a power module was below a rated range.

Procedure

1. Check whether the external power supply is normal. Check whether the external input of the power supply is within the input range of the power supply. If not, replace the external input of the power supply to ensure that the input of the power supply is within the normal range (180 V AC to 264 V AC). Check whether the alarm is cleared.

  • If yes, go to step 4.
  • If no, go to step 2.

2. Replace the power supply device. Then, check whether the alarm is cleared. Power off the faulty power module before replacing it.

Check whether the alarm is cleared.

  • If yes, go to step 4.
  • If no, go to step 3.

3. Collect alarm, log, and configuration information and contact Huawei technical support.

4. End.