DEVM/1/hwEntityInvalid_active: Physical entity failed. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=[67740], BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=Cause1:The board power was insufficient. Cause2:The device power was insufficient. Cause3:The number of power modules was less than required. Cause4:A power supply plane was unable to supply power with high reliability.)
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
BaseTrapSeverity |
To describe the level of trap. |
ProbableCause |
To describe the probable cause of trap. |
BaseTrapEventType |
To describe the type of trap. |
EntityPhysicalIndex |
The index of the physical entity. |
EntContainedIn |
The value of entPhysicalIndex for the physical entity. |
EntPhysicalName |
The textual name of the physical entity. |
RelativeResource |
This object may contain a key word to indicate the relative resource of an entity. |
ReasonDescription |
To describe the reason of trap in DisplayString style. |
Cause1:The board power was insufficient.
Cause2:The device power was insufficient.
Cause3:The number of power modules was less than required.
Cause4:A power supply plane was unable to supply power with high reliability.
1. If boards cannot be replaced, replace the power module with a high-power one. Then, check whether the alarm is cleared.
2. If boards can be replaced, replace the power module with a low-power one, or remove the unused boards. Then check whether the alarm is cleared.
3. Collect trap, log, and configuration information, and contact technical support.
4. End.