DEVM/1/hwEntityInvalid_active: Physical entity failed. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=[68015], BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=Cause 1:The PCI was abnormal. Cause 2:The internal clock of the PE or NSE was out of lock. Cause 3:The clock of the TCAM was out of lock.)
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
BaseTrapSeverity |
To describe the level of trap. |
ProbableCause |
To describe the probable cause of trap. |
BaseTrapEventType |
To describe the type of trap. |
EntityPhysicalIndex |
The index of the physical entity. |
EntContainedIn |
The value of entPhysicalIndex for the physical entity. |
EntPhysicalName |
The textual name of the physical entity. |
RelativeResource |
This object may contain a key word to indicate the relative resource of an entity. |
ReasonDescription |
To describe the reason of trap in DisplayString style. |
Cause 1:The PCI was abnormal.
Cause 2:The internal clock of the PE or NSE was out of lock.
Cause 3:The clock of the TCAM was out of lock.
1. Replace the board. After the new board is registered, check whether the alarm is cleared.
2. Collect trap, log, and configuration information, and contact technical support.
3. End.