DEVM/1/hwEntityInvalid_active-68169

Message

DEVM/1/hwEntityInvalid_active: Physical entity failed. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=[68169], BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=A power consumption limit was configured, resulting in inadequate system power supply.)

In VS mode, this log is supported only by the admin VS.

Description

Physical entity failed.

Parameters

Parameter Name Parameter Meaning

BaseTrapSeverity

To describe the level of trap.

ProbableCause

To describe the probable cause of trap.

BaseTrapEventType

To describe the type of trap.

EntityPhysicalIndex

The index of the physical entity.

EntContainedIn

The value of entPhysicalIndex for the physical entity.

EntPhysicalName

The textual name of the physical entity.

RelativeResource

This object may contain a key word to indicate the relative resource of an entity.

ReasonDescription

To describe the reason of trap in DisplayString style.

Possible Causes

A power consumption limit was configured, resulting in inadequate system power supply.

Procedure

1. Check whether the power modules configured are adequate for the system.

  • If so, go to Step 2.
  • If not, go to Step 3.

2. Check whether the power consumption limit configured is too low for system power supply. Reconfigure the capping power of the power supply. Then, check whether the alarm is cleared.

  • If so, go to Step 5.
  • If not, go to Step 3.

3. Insert the power module and check whether the alarm is cleared.

  • If so, go to Step 5.
  • If not, go to Step 4.

4. Collect trap, log, and configuration information, and contact technical support.

5. End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >