DEVM/1/hwEntityInvalid_clear

Message

DEVM/1/hwEntityInvalid_clear: A faulty physical entity recovered, and the fault caused by the faulty part was rectified. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=[ProbableCause], BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=[ReasonDescription])

In VS mode, this log is supported only by the admin VS.

Parameters

Parameter Name Parameter Meaning

BaseTrapSeverity

To describe the level of trap.

ProbableCause

To describe the probable cause of trap.

BaseTrapEventType

To describe the type of trap.

EntityPhysicalIndex

The index of the physical entity.

EntContainedIn

The value of entPhysicalIndex for the physical entity.

EntPhysicalName

The textual name of the physical entity.

RelativeResource

This object may contain a key word to indicate the relative resource of an entity.

ReasonDescription

To describe the reason of trap in DisplayString style.

Possible Causes

  • Cause 1:A link port on the MPU became up.
  • Cause 2:The faulty of An intra-chasssis channel between MPUs was cleared.
  • Cause 3:The faulty of An inter-chasssis channel between ICUs was cleared.
  • Cause 4:The faulty of An inter-chasssis channel between ICU and pannel eth0 of ICUs is cleared.
  • Cause 5:A port on the ICU is up.
  • Cause 6:The fault of a loop is formed between ICU(s), either because two connections are established between ICUs or two ports of the same ICU are interconnected is cleared.
  • Cause 7:Two MPUs of a CLC were connected to the different ICU.
  • Cause 8:Two MPUs of a CCC were correctly connected to ICUs.
  • Cause 9:An authorized device has connected with the cluster system.
  • Cause 65541:Vsr slot-id is resumed,the optical module is inserted.
  • Cause 66048:The board in-position signal is normal.
  • Cause 67587:The abnormality of key signals of the clock board is resolved.
  • Cause 67590:

    Multiple monitoring nodes recovered.

    A temperature sensor recovered.

  • Cause 67591:The hardware of the fan is normal.
  • Cause 67592:The hardware of the fan is normal.
  • Cause 67593:The power module is normal.
  • Cause 67594:The power supply module is present.
  • Cause 67595:The fan frame is present.
  • Cause 67596:The Liquid Crystal Display (LCD) is recovered from absent.
  • Cause 67597:The Liquid Crystal Display (LCD) is recovered from damaged.
  • Cause 67598:The Liquid Crystal Display (LCD) is recovered from failure.
  • Cause 67599:The cables of the fan frame is present.
  • Cause 67600:The Liquid Crystal Display (LCD) cable is recovered from absent.
  • Cause 67601:The power cables is present.
  • Cause 67602:The EEPROM component fails was cleared.
  • Cause 67603:The Monitor bus faulty was cleared.
  • Cause 67604:The communication of the Monitor bus's fail was cleared. This trap indicates that the Monitor bus fault was rectified.
  • Cause 67608:The output voltage of a power module is normal.
  • Cause 67609:The output voltage of a power module is normal.
  • Cause 67610:The output voltage of a power module is normal.
  • Cause 67611:The output voltage of a power module is normal.
  • Cause 67612:The output voltage of a power module is normal.
  • Cause 67613:The current of a power module is normal.
  • Cause 67614:The power module's output is normal.
  • Cause 67615:The input voltage of a power module is normal.
  • Cause 67616:The input voltage of a power module is normal.
  • Cause 67617:The input voltage of a power module is normal.
  • Cause 67618:The input voltage of a power module is normal.
  • Cause 67619:The input voltage of a power module is normal.
  • Cause 67620:The alarm indicating that the internal temperature of the power supply module exceeded the upper threshold was cleared.
  • Cause 67621:The alarm indicating that the internal temperature of the power supply module was too high was cleared.
  • Cause 67622:The board recovered.
  • Cause 67623:The board recovered.
  • Cause 67624:The fault occurred on the internal processor of a power module was cleared.
  • Cause 67625:The alarm indicating that the communication between the power supply module and the device was abnormal was cleared.
  • Cause 67626:The alarm indicating that the fan of the power supply module was abnormal was cleared.
  • Cause 67627:The alarm indicating that the input fuse of the power supply module was abnormal or the link was disconnected was cleared.
  • Cause 67628:The alarm indicating that the input fuse of the power supply module was abnormal or the link was disconnected was cleared.
  • Cause 67629:

    The first power supply was switched on.

    The second power supply was switched on.

  • Cause 67630:The alarm indicating that one of the internal arresters of the power supply module was abnormal was cleared.
  • Cause 67631:The alarm indicating that the output voltage of the power supply module was abnormal was cleared.
  • Cause 67632:The alarm indicating that the DC auxiliary input voltage was lower than the rated voltage was cleared.
  • Cause 67633:The power supply module was in position or the power supply module recovered.
  • Cause 67634:The alarm indicating that the I2C power module was abnormal was cleared.
  • Cause 67638:The alarm indicating that the power supply module was properly installed but not powered on was cleared.
  • Cause 67642:The abnormality of key components of the clock board is resolved.
  • Cause 67643:The 2M PLL of the clock board is restored to the locked state.
  • Cause 67644:The sending and receiving of heartbeat packets on the clock board is restored.
  • Cause 67652:The alarm indicating that the reference clock source on the board was faulty was cleared.
  • Cause 67653:The SFU clock source was recovered.
  • Cause 67654:LPU slot slotID is resumed,the key chip of the TMtmID is normal.
  • Cause 67656:LPU slot slotID is resumed,the key chip of the TMtmID is normal.
  • Cause 67657:LPU slot slotID is resumed,the data link status to PE of the TMtmID is normal.
  • Cause 67659:The alarm indicating that the signal carrying information about the slot where the interface board resided was disturbed was cleared.
  • Cause 67660:

    The second 48 V power supply recovered.

    One or both power supplies recovered.

    The two PMU monitor buses recovered.

  • Cause 67661:The mpu act signal of the Board is normal.
  • Cause 67669:The fault on the FE was cleared.
  • Cause 67688:The optical module temperature is normal.
  • Cause 67689:The optical module temperature is normal.
  • Cause 67690:The optical module voltage is normal.
  • Cause 67691:The optical module temperature is normal.
  • Cause 67692:the optical module bias is normal.
  • Cause 67693:the optical module bias is normal.
  • Cause 67694:The alarm indicating that the transmitting power of the optical module was too high was cleared.
  • Cause 67695:The alarm indicating that the transmitting power of the optical module was too low was cleared.
  • Cause 67696:The alarm indicating that the receiving power of the optical module was too high was cleared.
  • Cause 67697:The alarm indicating that the receiving power of the optical module was too low was cleared.
  • Cause 67701:The alarm indicating that the clock signals of the MPU were faulty was cleared.
  • Cause 67708:The alarm indicating that the power of the FCB was faulty was cleared.
  • Cause 67709:The control bus of the NSE module recovered.
  • Cause 67721:LPU slot slotIDis resumed,the link number to fabric of the TMtmID is enough.
  • Cause 67722:The mpu act signal of the Board is recovered.
  • Cause 67726:The alarm indicating that the batteries on the MPU were abnormal was cleared.
  • Cause 67727:The link between the FE and PIC recovers.
  • Cause 67734:The mpu act signal of the Board is recovered.
  • Cause 67735:The alarm indicating that the EEPROM of the power supply module was damaged was cleared.
  • Cause 67737:The alarm indicating that the I2C channel was faulty was cleared.
  • Cause 67739:The alarm indicating that the sensor on the subcard or the board was faulty was cleared.
  • Cause 67740:

    The board power recovered.

    The device power recovered.

    The number of power modules fell below the upper limit.

    A power supply plane became able to supply power with high reliability.

  • Cause 67743:Vsr VsrId is resumed, the optical module of the OFC is normal.
  • Cause 67744:125 MHz Clock fault of the board rectified.
  • Cause 67745:LPU slot slotID is resumed,the key chip of the TMtmID is normal.
  • Cause 67746:Vsr VsrId is resumed,the optic connection is normal.
  • Cause 67755:The flash of MPU or LPU or SFU is normal.
  • Cause 67762:SFU in chassis chassisid is full.
  • Cause 67763:MPU in chassis chassisid is full.
  • Cause 67765:

    The software of the board fault is cleared.

    The hardware of the TCAM fault is cleared.

    The hardware of the ASE fault is cleared.

  • Cause 67771:EPLD Fault rectified.
  • Cause 67796:The alarm indicating that the ASE's faulty was cleared.
  • Cause 67837:NSE data links recovered.
  • Cause 67838:The alarm indicating that the hardware of the TCAM chip's faulty was cleared.
  • Cause 67840:ECC detected faults when the memory read and wrote DDR SDRAM of the CPU is cleared.
  • Cause 67842:The alarm indicating that the signal for the board being properly installed was incorrect was cleared.
  • Cause 67900:LPU slot slotID is resumed,the key chip of the TMtmID is normal.
  • Cause 67905:LPU slot slotID is resumed,the key chip of the TMtmID is normal.
  • Cause 67921:SWF slot slot-id is resumed, all the links of the board are available.
  • Cause 67922:The pem type matchs the type of the backplane.
  • Cause 67923:The fan type matchs the type of the backplane.
  • Cause 67924:Slot slotID matches the device.
  • Cause 67952:The alarm indicating that logic 1 of the board failed was cleared.
  • Cause 67953:The alarm indicating that logic 2 of the board failed was cleared.
  • Cause 67969:The adaptive clock translator's output of the Board resumed.
  • Cause 67970:The alarm indicating that the 33 MHz clock on an interface board failed was cleared.
  • Cause 67971:A communication failure occurred on the fan module is cleared.
  • Cause 67995:The air filter inside the chassis is cleaned
  • Cause 67999:The slotID check's fail is cleared.
  • Cause 68006:The clock signal level3Clock of clock board is normal.
  • Cause 68007:The clock signal 3Clock of board is normal.
  • Cause 68008:The first erode-protect unit break is cleared.
  • Cause 68010:The control bus PCIE of board is normal.
  • Cause 68011:The cpu internal module of the board is normal.
  • Cause 68015:The alarm indicating that a reading/writing fault occurred on the PE TCAM component was cleared.
  • Cause 68016:The alarm indicating that a transmission fault occurred on the PE SPI was cleared.
  • Cause 68017:The alarm indicating that a PE PLL fault occurred was cleared.
  • Cause 68018:The alarm indicating that the OutPut PLL fault occurred on the PE component was rectified.
  • Cause 68035:The monitor bus detected previously-lost clock signals on a board.
  • Cause 68040:The alarm indicating that a fault occurred on the FPGA component of the PIC card was cleared.
  • Cause 68043:SFU clock fault was rectified.
  • Cause 68049:The fault detected by the BSP module on the key chip EEPROM or IIC bus on a board is rectified.
  • Cause 68050:The usb device fail was cleared.
  • Cause 68051:The key chip GE LSW of the Board is normal.
  • Cause 68052:The key chip FE LSW of the Board is normal.
  • Cause 68054:Error in network board PHY was rectified.
  • Cause 68055:The SFU clock synchronization is normal.
  • Cause 68056:The mdio bus of this port is normal.
  • Cause 68057:The clock unit on the subcard was faulty.
  • Cause 68059:The optical transceiver of the PIC recovered.
  • Cause 68060:The alarm indicating that a key chip on a PIC card was faulty was cleared.
  • Cause 68062:The alarm indicating that a key chip on a PIC card was faulty was cleared.
  • Cause 68064:The alarm indicating that a key chip on a PIC card was faulty was cleared.
  • Cause 68065:The alarm indicating that a fault occurred on the data channel component of the PIC card was cleared.
  • Cause 68067:The alarm indicating that a fault occurred on the data channel component of the PIC card was cleared.
  • Cause 68074:The output voltage of slot fail is cleared.
  • Cause 68085:The fault of too many SFU links were shut down for crc, loopback, FDR, updown is cleared.
  • Cause 68095:The alarm indicating that the optical module type did not match the interface type was cleared.
  • Cause 68130:Power current not average fault is cleared.
  • Cause 68131:Power canbus is normal.
  • Cause 68132:Power current exceed the max value fault is cleared.
  • Cause 68133:Power module merge current fail is cleared.
  • Cause 68134:The RTC clock is recovered from abnormal.
  • Cause 68135:A PMU fault was rectified.
  • Cause 68136:The PMU canbus is recovered from abnormal.
  • Cause 68137:The cable and powerbackplane is connected.
  • Cause 68138:Fan link board online.
  • Cause 68140:The fault of the CPU on the interface board was rectified.
  • Cause 68143:The fast switchover port portIDof MPU slotID is recovered.
  • Cause 68144:The fast switchover port portIDof MPU slotID is recovered.
  • Cause 68147:The number of error packets reached or exceeded the threshold fault is cleared.
  • Cause 68148:The number of lost packets reached or exceeded the threshold fault is cleared.
  • Cause 68153:

    The PE chip is normal.

    PE FORWARD TABLE is normal.

  • Cause 68154:The PMU offline fault was rectified.
  • Cause 68155:The fault about the insufficient power supply was rectified.
  • Cause 68156:The fault that the number of PMs was below the threshold was rectified.
  • Cause 68157:The fault about one or two external power inputs of the power module was rectified.
  • Cause 68160:The PLD or Flash initializatiaon was restored to normal.
  • Cause 68161:The power supply was restored to normal.
  • Cause 68162:the CFP checksum was restored to normal.
  • Cause 68163:The fan frame is present.
  • Cause 68165:The chassis-type is compatible with the master one.
  • Cause 68166:The?OFC?matchs the?CXPs.
  • Cause 68167:The license item is normal.
  • Cause 68168:The license item is normal.
  • Cause 68169:The power supply is enough.
  • Cause 68170:The app of the power module is normal.
  • Cause 68171:The cpu frequency of the board is normal.
  • Cause 68172:CPU fault was rectified.
  • Cause 68175:Installed the fan stably.
  • Cause 68176:The communication between the CMUs is normal.
  • Cause 68177:The dustproof gate is closed.
  • Cause 68178:The CMU is registered.
  • Cause 68179:Fan in the chassis chassisid is full.
  • Cause 68180:CMU matches with product brand.
  • Cause 68181:The CMU communication or signal is normal.
  • Cause 68182:The channel between the power module and the device is ok.
  • Cause 68183:The power supply on the power module is normal.
  • Cause 68184:The power type matches the type of the backplane.
  • Cause 68185:CMUs were fully configured.
  • Cause 68187:The fan type matchs the type of the sfu.
  • Cause 68190:The PTN mode of the master chassis in a virtual cluster device is same as that of the slave chassis.
  • Cause 68191:The actual power-on status of the chip is as expected.
  • Cause 68197:The temperature of the secondary CDU is restored to the normal range.
  • Cause 68198:The pressure of the secondary CDU is restored to the normal range.
  • Cause 68205:Liquid leakage fault rectified.
  • Cause 68206:The valve fault is rectified.
  • Cause 68214:AC fault rectified.
  • Cause 68218:The CDU communication fault is rectified.
  • Cause 68224:The smi serial of the board is normal.
  • Cause 68225:IPUs with different forwarding capabilities were inserted on the device.
  • Cause 68226:SFU MPI control bus fault was rectified. This trap message is informational only, and no action is required.
  • Cause 68227:Device certificate verify success.
  • Cause 68229:The CPU MCU is normal
  • Cause 68232:Fan power unlocking succeeds.
  • Cause 69131:The board was powered on.
  • Cause 69501:The interrupted power input channel recovered.
  • Cause 69502:The filtering box was properly installed again.
  • Cause 69503:CMU switch is normal.
  • Cause 69505:The fault on the PCIE/PCI interface on the FE is rectified..
  • Cause 69507:The fault indicating that the data link of the interface logic on a board was abnormal was rectified.
  • Cause 69510:LPU slot slotID is failed,the interlaken to PIC of the PE is normal.
  • Cause 69512:The fault in the subcard was rectified.
  • Cause 69517:The fuse is recovered from absent.
  • Cause 69632:QDR storage device on a forwarding chip of a board recovered.
  • Cause 69634:LPU slot slotID is resumed,the inner status of the TMtmID is normal.
  • Cause 132631:The packet loss count of TM on slot slotid below the alarm threshold.
  • Cause 132648:SFU MPI control bus fault was rectified.

Procedure

  • Cause 1:A link port on the MPU became up.

    This message is informational only, and no action is required.

  • Cause 2:The faulty of An intra-chasssis channel between MPUs was cleared.

    This message is informational only, and no action is required.

  • Cause 3:The faulty of An inter-chasssis channel between ICUs was cleared.

    This message is informational only, and no action is required.

  • Cause 4:The faulty of An inter-chasssis channel between ICU and pannel eth0 of ICUs is cleared.

    This message is informational only, and no action is required.

  • Cause 5:A port on the ICU is up.

    This message is informational only, and no action is required.

  • Cause 6:The fault of a loop is formed between ICU(s), either because two connections are established between ICUs or two ports of the same ICU are interconnected is cleared.

    This message is informational only, and no action is required.

  • Cause 7:Two MPUs of a CLC were connected to the different ICU.

    This message is informational only, and no action is required.

  • Cause 8:Two MPUs of a CCC were correctly connected to ICUs.

    This message is informational only, and no action is required.

  • Cause 9:An authorized device has connected with the cluster system.

    This message is informational only, and no action is required.

  • Cause 65541:Vsr slot-id is resumed,the optical module is inserted.

    This message is informational only, and no action is required.

  • Cause 66048:The board in-position signal is normal.

    This message is informational only, and no action is required.

  • Cause 67587:The abnormality of key signals of the clock board is resolved.

    This message is informational only, and no action is required.

  • Cause 67590:

    Multiple monitoring nodes recovered.

    A temperature sensor recovered.

    This message is informational only, and no action is required.

  • Cause 67591:The hardware of the fan is normal.

    This message is informational only, and no action is required.

  • Cause 67592:The hardware of the fan is normal.

    This message is informational only, and no action is required.

  • Cause 67593:The power module is normal.

    This message is informational only, and no action is required.

  • Cause 67594:The power supply module is present.

    This message is informational only, and no action is required.

  • Cause 67595:The fan frame is present.

    This message is informational only, and no action is required.

  • Cause 67596:The Liquid Crystal Display (LCD) is recovered from absent.

    This message is informational only, and no action is required.

  • Cause 67597:The Liquid Crystal Display (LCD) is recovered from damaged.

    This message is informational only, and no action is required.

  • Cause 67598:The Liquid Crystal Display (LCD) is recovered from failure.

    This message is informational only, and no action is required.

  • Cause 67599:The cables of the fan frame is present.

    This message is informational only, and no action is required.

  • Cause 67600:The Liquid Crystal Display (LCD) cable is recovered from absent.

    This message is informational only, and no action is required.

  • Cause 67601:The power cables is present.

    This message is informational only, and no action is required.

  • Cause 67602:The EEPROM component fails was cleared.

    This message is informational only, and no action is required.

  • Cause 67603:The Monitor bus faulty was cleared.

    This message is informational only, and no action is required.

  • Cause 67604:The communication of the Monitor bus's fail was cleared. This trap indicates that the Monitor bus fault was rectified.

    This message is informational only, and no action is required.

  • Cause 67608:The output voltage of a power module is normal.

    This message is informational only, and no action is required.

  • Cause 67609:The output voltage of a power module is normal.

    This message is informational only, and no action is required.

  • Cause 67610:The output voltage of a power module is normal.

    This message is informational only, and no action is required.

  • Cause 67611:The output voltage of a power module is normal.

    This message is informational only, and no action is required.

  • Cause 67612:The output voltage of a power module is normal.

    This message is informational only, and no action is required.

  • Cause 67613:The current of a power module is normal.

    This message is informational only, and no action is required.

  • Cause 67614:The power module's output is normal.

    This message is informational only, and no action is required.

  • Cause 67615:The input voltage of a power module is normal.

    This message is informational only, and no action is required.

  • Cause 67616:The input voltage of a power module is normal.

    This message is informational only, and no action is required.

  • Cause 67617:The input voltage of a power module is normal.

    This message is informational only, and no action is required.

  • Cause 67618:The input voltage of a power module is normal.

    This message is informational only, and no action is required.

  • Cause 67619:The input voltage of a power module is normal.

    This message is informational only, and no action is required.

  • Cause 67620:The alarm indicating that the internal temperature of the power supply module exceeded the upper threshold was cleared.

    This message is informational only, and no action is required.

  • Cause 67621:The alarm indicating that the internal temperature of the power supply module was too high was cleared.

    This message is informational only, and no action is required.

  • Cause 67622:The board recovered.

    This message is informational only, and no action is required.

  • Cause 67623:The board recovered.

    This message is informational only, and no action is required.

  • Cause 67624:The fault occurred on the internal processor of a power module was cleared.

    This message is informational only, and no action is required.

  • Cause 67625:The alarm indicating that the communication between the power supply module and the device was abnormal was cleared.

    This message is informational only, and no action is required.

  • Cause 67626:The alarm indicating that the fan of the power supply module was abnormal was cleared.

    This message is informational only, and no action is required.

  • Cause 67627:The alarm indicating that the input fuse of the power supply module was abnormal or the link was disconnected was cleared.

    This message is informational only, and no action is required.

  • Cause 67628:The alarm indicating that the input fuse of the power supply module was abnormal or the link was disconnected was cleared.

    This message is informational only, and no action is required.

  • Cause 67629:

    The first power supply was switched on.

    The second power supply was switched on.

    This message is informational only, and no action is required.

  • Cause 67630:The alarm indicating that one of the internal arresters of the power supply module was abnormal was cleared.

    This message is informational only, and no action is required.

  • Cause 67631:The alarm indicating that the output voltage of the power supply module was abnormal was cleared.

    This message is informational only, and no action is required.

  • Cause 67632:The alarm indicating that the DC auxiliary input voltage was lower than the rated voltage was cleared.

    This message is informational only, and no action is required.

  • Cause 67633:The power supply module was in position or the power supply module recovered.

    This message is informational only, and no action is required.

  • Cause 67634:The alarm indicating that the I2C power module was abnormal was cleared.

    This message is informational only, and no action is required.

  • Cause 67638:The alarm indicating that the power supply module was properly installed but not powered on was cleared.

    This message is informational only, and no action is required.

  • Cause 67642:The abnormality of key components of the clock board is resolved.

    This message is informational only, and no action is required.

  • Cause 67643:The 2M PLL of the clock board is restored to the locked state.

    This message is informational only, and no action is required.

  • Cause 67644:The sending and receiving of heartbeat packets on the clock board is restored.

    This message is informational only, and no action is required.

  • Cause 67652:The alarm indicating that the reference clock source on the board was faulty was cleared.

    This message is informational only, and no action is required.

  • Cause 67653:The SFU clock source was recovered.

    This message is informational only, and no action is required.

  • Cause 67654:LPU slot slotID is resumed,the key chip of the TMtmID is normal.

    This message is informational only, and no action is required.

  • Cause 67656:LPU slot slotID is resumed,the key chip of the TMtmID is normal.

    This message is informational only, and no action is required.

  • Cause 67657:LPU slot slotID is resumed,the data link status to PE of the TMtmID is normal.

    This message is informational only, and no action is required.

  • Cause 67659:The alarm indicating that the signal carrying information about the slot where the interface board resided was disturbed was cleared.

    This message is informational only, and no action is required.

  • Cause 67660:

    The second 48 V power supply recovered.

    One or both power supplies recovered.

    The two PMU monitor buses recovered.

    This message is informational only, and no action is required.

  • Cause 67661:The mpu act signal of the Board is normal.

    This message is informational only, and no action is required.

  • Cause 67669:The fault on the FE was cleared.

    This message is informational only, and no action is required.

  • Cause 67688:The optical module temperature is normal.

    This message is informational only, and no action is required.

  • Cause 67689:The optical module temperature is normal.

    This message is informational only, and no action is required.

  • Cause 67690:The optical module voltage is normal.

    This message is informational only, and no action is required.

  • Cause 67691:The optical module temperature is normal.

    This message is informational only, and no action is required.

  • Cause 67692:the optical module bias is normal.

    This message is informational only, and no action is required.

  • Cause 67693:the optical module bias is normal.

    This message is informational only, and no action is required.

  • Cause 67694:The alarm indicating that the transmitting power of the optical module was too high was cleared.

    This message is informational only, and no action is required.

  • Cause 67695:The alarm indicating that the transmitting power of the optical module was too low was cleared.

    This message is informational only, and no action is required.

  • Cause 67696:The alarm indicating that the receiving power of the optical module was too high was cleared.

    This message is informational only, and no action is required.

  • Cause 67697:The alarm indicating that the receiving power of the optical module was too low was cleared.

    This message is informational only, and no action is required.

  • Cause 67701:The alarm indicating that the clock signals of the MPU were faulty was cleared.

    This message is informational only, and no action is required.

  • Cause 67708:The alarm indicating that the power of the FCB was faulty was cleared.

    This message is informational only, and no action is required.

  • Cause 67709:The control bus of the NSE module recovered.

    This message is informational only, and no action is required.

  • Cause 67721:LPU slot slotIDis resumed,the link number to fabric of the TMtmID is enough.

    This message is informational only, and no action is required.

  • Cause 67722:The mpu act signal of the Board is recovered.

    This message is informational only, and no action is required.

  • Cause 67726:The alarm indicating that the batteries on the MPU were abnormal was cleared.

    This message is informational only, and no action is required.

  • Cause 67727:The link between the FE and PIC recovers.

    This message is informational only, and no action is required.

  • Cause 67734:The mpu act signal of the Board is recovered.

    This message is informational only, and no action is required.

  • Cause 67735:The alarm indicating that the EEPROM of the power supply module was damaged was cleared.

    This message is informational only, and no action is required.

  • Cause 67737:The alarm indicating that the I2C channel was faulty was cleared.

    This message is informational only, and no action is required.

  • Cause 67739:The alarm indicating that the sensor on the subcard or the board was faulty was cleared.

    This message is informational only, and no action is required.

  • Cause 67740:

    The board power recovered.

    The device power recovered.

    The number of power modules fell below the upper limit.

    A power supply plane became able to supply power with high reliability.

    This message is informational only, and no action is required.

  • Cause 67743:Vsr VsrId is resumed, the optical module of the OFC is normal.

    This message is informational only, and no action is required.

  • Cause 67744:125 MHz Clock fault of the board rectified.

    This message is informational only, and no action is required.

  • Cause 67745:LPU slot slotID is resumed,the key chip of the TMtmID is normal.

    This message is informational only, and no action is required.

  • Cause 67746:Vsr VsrId is resumed,the optic connection is normal.

    This message is informational only, and no action is required.

  • Cause 67755:The flash of MPU or LPU or SFU is normal.

    This message is informational only, and no action is required.

  • Cause 67762:SFU in chassis chassisid is full.

    This message is informational only, and no action is required.

  • Cause 67763:MPU in chassis chassisid is full.

    This message is informational only, and no action is required.

  • Cause 67765:

    The software of the board fault is cleared.

    The hardware of the TCAM fault is cleared.

    The hardware of the ASE fault is cleared.

    This message is informational only, and no action is required.

  • Cause 67771:EPLD Fault rectified.

    This message is informational only, and no action is required.

  • Cause 67796:The alarm indicating that the ASE's faulty was cleared.

    This message is informational only, and no action is required.

  • Cause 67837:NSE data links recovered.

    This message is informational only, and no action is required.

  • Cause 67838:The alarm indicating that the hardware of the TCAM chip's faulty was cleared.

    This message is informational only, and no action is required.

  • Cause 67840:ECC detected faults when the memory read and wrote DDR SDRAM of the CPU is cleared.

    This message is informational only, and no action is required.

  • Cause 67842:The alarm indicating that the signal for the board being properly installed was incorrect was cleared.

    This message is informational only, and no action is required.

  • Cause 67900:LPU slot slotID is resumed,the key chip of the TMtmID is normal.

    This message is informational only, and no action is required.

  • Cause 67905:LPU slot slotID is resumed,the key chip of the TMtmID is normal.

    This message is informational only, and no action is required.

  • Cause 67921:SWF slot slot-id is resumed, all the links of the board are available.

    This message is informational only, and no action is required.

  • Cause 67922:The pem type matchs the type of the backplane.

    This message is informational only, and no action is required.

  • Cause 67923:The fan type matchs the type of the backplane.

    This message is informational only, and no action is required.

  • Cause 67924:Slot slotID matches the device.

    This message is informational only, and no action is required.

  • Cause 67952:The alarm indicating that logic 1 of the board failed was cleared.

    This message is informational only, and no action is required.

  • Cause 67953:The alarm indicating that logic 2 of the board failed was cleared.

    This message is informational only, and no action is required.

  • Cause 67969:The adaptive clock translator's output of the Board resumed.

    This message is informational only, and no action is required.

  • Cause 67970:The alarm indicating that the 33 MHz clock on an interface board failed was cleared.

    This message is informational only, and no action is required.

  • Cause 67971:A communication failure occurred on the fan module is cleared.

    This message is informational only, and no action is required.

  • Cause 67995:The air filter inside the chassis is cleaned

    This message is informational only, and no action is required.

  • Cause 67999:The slotID check's fail is cleared.

    This message is informational only, and no action is required.

  • Cause 68006:The clock signal level3Clock of clock board is normal.

    This message is informational only, and no action is required.

  • Cause 68007:The clock signal 3Clock of board is normal.

    This message is informational only, and no action is required.

  • Cause 68008:The first erode-protect unit break is cleared.

    This message is informational only, and no action is required.

  • Cause 68010:The control bus PCIE of board is normal.

    This message is informational only, and no action is required.

  • Cause 68011:The cpu internal module of the board is normal.

    This message is informational only, and no action is required.

  • Cause 68015:The alarm indicating that a reading/writing fault occurred on the PE TCAM component was cleared.

    This message is informational only, and no action is required.

  • Cause 68016:The alarm indicating that a transmission fault occurred on the PE SPI was cleared.

    This message is informational only, and no action is required.

  • Cause 68017:The alarm indicating that a PE PLL fault occurred was cleared.

    This message is informational only, and no action is required.

  • Cause 68018:The alarm indicating that the OutPut PLL fault occurred on the PE component was rectified.

    This message is informational only, and no action is required.

  • Cause 68035:The monitor bus detected previously-lost clock signals on a board.

    This message is informational only, and no action is required.

  • Cause 68040:The alarm indicating that a fault occurred on the FPGA component of the PIC card was cleared.

    This message is informational only, and no action is required.

  • Cause 68043:SFU clock fault was rectified.

    This message is informational only, and no action is required.

  • Cause 68049:The fault detected by the BSP module on the key chip EEPROM or IIC bus on a board is rectified.

    This message is informational only, and no action is required.

  • Cause 68050:The usb device fail was cleared.

    This message is informational only, and no action is required.

  • Cause 68051:The key chip GE LSW of the Board is normal.

    This message is informational only, and no action is required.

  • Cause 68052:The key chip FE LSW of the Board is normal.

    This message is informational only, and no action is required.

  • Cause 68054:Error in network board PHY was rectified.

    This message is informational only, and no action is required.

  • Cause 68055:The SFU clock synchronization is normal.

    This message is informational only, and no action is required.

  • Cause 68056:The mdio bus of this port is normal.

    This message is informational only, and no action is required.

  • Cause 68057:The clock unit on the subcard was faulty.

    This message is informational only, and no action is required.

  • Cause 68059:The optical transceiver of the PIC recovered.

    This message is informational only, and no action is required.

  • Cause 68060:The alarm indicating that a key chip on a PIC card was faulty was cleared.

    This message is informational only, and no action is required.

  • Cause 68062:The alarm indicating that a key chip on a PIC card was faulty was cleared.

    This message is informational only, and no action is required.

  • Cause 68064:The alarm indicating that a key chip on a PIC card was faulty was cleared.

    This message is informational only, and no action is required.

  • Cause 68065:The alarm indicating that a fault occurred on the data channel component of the PIC card was cleared.

    This message is informational only, and no action is required.

  • Cause 68067:The alarm indicating that a fault occurred on the data channel component of the PIC card was cleared.

    This message is informational only, and no action is required.

  • Cause 68074:The output voltage of slot fail is cleared.

    This message is informational only, and no action is required.

  • Cause 68085:The fault of too many SFU links were shut down for crc, loopback, FDR, updown is cleared.

    This message is informational only, and no action is required.

  • Cause 68095:The alarm indicating that the optical module type did not match the interface type was cleared.

    This message is informational only, and no action is required.

  • Cause 68130:Power current not average fault is cleared.

    This message is informational only, and no action is required.

  • Cause 68131:Power canbus is normal.

    This message is informational only, and no action is required.

  • Cause 68132:Power current exceed the max value fault is cleared.

    This message is informational only, and no action is required.

  • Cause 68133:Power module merge current fail is cleared.

    This message is informational only, and no action is required.

  • Cause 68134:The RTC clock is recovered from abnormal.

    This message is informational only, and no action is required.

  • Cause 68135:A PMU fault was rectified.

    This message is informational only, and no action is required.

  • Cause 68136:The PMU canbus is recovered from abnormal.

    This message is informational only, and no action is required.

  • Cause 68137:The cable and powerbackplane is connected.

    This message is informational only, and no action is required.

  • Cause 68138:Fan link board online.

    This message is informational only, and no action is required.

  • Cause 68140:The fault of the CPU on the interface board was rectified.

    This message is informational only, and no action is required.

  • Cause 68143:The fast switchover port portIDof MPU slotID is recovered.

    This message is informational only, and no action is required.

  • Cause 68144:The fast switchover port portIDof MPU slotID is recovered.

    This message is informational only, and no action is required.

  • Cause 68147:The number of error packets reached or exceeded the threshold fault is cleared.

    This message is informational only, and no action is required.

  • Cause 68148:The number of lost packets reached or exceeded the threshold fault is cleared.

    This message is informational only, and no action is required.

  • Cause 68153:

    The PE chip is normal.

    PE FORWARD TABLE is normal.

    This message is informational only, and no action is required.

  • Cause 68154:The PMU offline fault was rectified.

    This message is informational only, and no action is required.

  • Cause 68155:The fault about the insufficient power supply was rectified.

    This message is informational only, and no action is required.

  • Cause 68156:The fault that the number of PMs was below the threshold was rectified.

    This message is informational only, and no action is required.

  • Cause 68157:The fault about one or two external power inputs of the power module was rectified.

    This message is informational only, and no action is required.

  • Cause 68160:The PLD or Flash initializatiaon was restored to normal.

    This message is informational only, and no action is required.

  • Cause 68161:The power supply was restored to normal.

    This message is informational only, and no action is required.

  • Cause 68162:the CFP checksum was restored to normal.

    This message is informational only, and no action is required.

  • Cause 68163:The fan frame is present.

    This message is informational only, and no action is required.

  • Cause 68165:The chassis-type is compatible with the master one.

    This message is informational only, and no action is required.

  • Cause 68166:The?OFC?matchs the?CXPs.

    This message is informational only, and no action is required.

  • Cause 68167:The license item is normal.

    This message is informational only, and no action is required.

  • Cause 68168:The license item is normal.

    This message is informational only, and no action is required.

  • Cause 68169:The power supply is enough.

    This message is informational only, and no action is required.

  • Cause 68170:The app of the power module is normal.

    This message is informational only, and no action is required.

  • Cause 68171:The cpu frequency of the board is normal.

    This message is informational only, and no action is required.

  • Cause 68172:CPU fault was rectified.

    This message is informational only, and no action is required.

  • Cause 68175:Installed the fan stably.

    This message is informational only, and no action is required.

  • Cause 68176:The communication between the CMUs is normal.

    This message is informational only, and no action is required.

  • Cause 68177:The dustproof gate is closed.

    This message is informational only, and no action is required.

  • Cause 68178:The CMU is registered.

    This message is informational only, and no action is required.

  • Cause 68179:Fan in the chassis chassisid is full.

    This message is informational only, and no action is required.

  • Cause 68180:CMU matches with product brand.

    This message is informational only, and no action is required.

  • Cause 68181:The CMU communication or signal is normal.

    This message is informational only, and no action is required.

  • Cause 68182:The channel between the power module and the device is ok.

    This message is informational only, and no action is required.

  • Cause 68183:The power supply on the power module is normal.

    This message is informational only, and no action is required.

  • Cause 68184:The power type matches the type of the backplane.

    This message is informational only, and no action is required.

  • Cause 68185:CMUs were fully configured.

    This message is informational only, and no action is required.

  • Cause 68187:The fan type matchs the type of the sfu.

    This message is informational only, and no action is required.

  • Cause 68190:The PTN mode of the master chassis in a virtual cluster device is same as that of the slave chassis.

    This message is informational only, and no action is required.

  • Cause 68191:The actual power-on status of the chip is as expected.

    This message is information only,and on action is required.

  • Cause 68197:The temperature of the secondary CDU is restored to the normal range.

    This message is informational only, and no action is required.

  • Cause 68198:The pressure of the secondary CDU is restored to the normal range.

    This message is informational only, and no action is required.

  • Cause 68205:Liquid leakage fault rectified.

    This message is informational only, and no action is required.

  • Cause 68206:The valve fault is rectified.

    This message is informational only, and no action is required.

  • Cause 68214:AC fault rectified.

    This message is informational only, and no action is required.

  • Cause 68218:The CDU communication fault is rectified.

    This message is informational only, and no action is required.

  • Cause 68224:The smi serial of the board is normal.

    This message is informational only, and no action is required.

  • Cause 68225:IPUs with different forwarding capabilities were inserted on the device.

    This message is informational only, and no action is required.

  • Cause 68226:SFU MPI control bus fault was rectified. This trap message is informational only, and no action is required.

    This message is informational only, and no action is required.

  • Cause 68227:Device certificate verify success.

    This message is informational only, and no action is required.

  • Cause 68229:The CPU MCU is normal

    This message is informational only, and no action is required.

  • Cause 68232:Fan power unlocking succeeds.

    This message is informational only, and no action is required.

  • Cause 69131:The board was powered on.

    This message is informational only, and no action is required.

  • Cause 69501:The interrupted power input channel recovered.

    This message is informational only, and no action is required.

  • Cause 69502:The filtering box was properly installed again.

    This message is informational only, and no action is required.

  • Cause 69503:CMU switch is normal.

    This message is informational only, and no action is required.

  • Cause 69505:The fault on the PCIE/PCI interface on the FE is rectified..

    This message is informational only, and no action is required.

  • Cause 69507:The fault indicating that the data link of the interface logic on a board was abnormal was rectified.

    This message is informational only, and no action is required.

  • Cause 69510:LPU slot slotID is failed,the interlaken to PIC of the PE is normal.

    This message is informational only, and no action is required.

  • Cause 69512:The fault in the subcard was rectified.

    This message is informational only, and no action is required.

  • Cause 69517:The fuse is recovered from absent.

    This message is informational only, and no action is required.

  • Cause 69632:QDR storage device on a forwarding chip of a board recovered.

    This message is informational only, and no action is required.

  • Cause 69634:LPU slot slotID is resumed,the inner status of the TMtmID is normal.

    This message is informational only, and no action is required.

  • Cause 132631:The packet loss count of TM on slot slotid below the alarm threshold.

    This message is informational only, and no action is required.

  • Cause 132648:SFU MPI control bus fault was rectified.

    This message is informational only, and no action is required.