DEVM/2/hwEthRxFlowFallAlarm_active

Message

DEVM/2/hwEthRxFlowFallAlarm_active: Traffic fall alarm in the receive direction of an Ethernet interface.(hwPhysicalPortIfIndex=[hwPhysicalPortIfIndex], hwPhysicalPortName=[hwPhysicalPortName])

Description

Traffic fall alarm in the receive direction of an Ethernet interface.

Parameters

Parameter Name Parameter Meaning

hwPhysicalPortIfIndex

Index of physical port.

hwPhysicalPortName

Name of physical port.

Possible Causes

When an interface is up, traffic fall monitoring is enabled. If the average traffic in the first two measurement periods is greater than 1 Mbit/s but the average traffic in the current measurement period is less than 10 kbit/s, it indicates that the traffic decreases sharply. In this case, a traffic fall alarm is generated. Each monitoring period is 2 minutes.

Procedure

The alarm is automatically cleared after the first 2-minute period elapses.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.