ARP/4/hwEthernetARPThresholdExceedAlarm_active: The number of ARP entries exceeded the threshold. (entPhysicalIndex=[entPhysicalIndex], Slot name=[slotname], Threshold=[Threshold], Number of dynamic ARP entries=[DynEntries], Number of static ARP entries=[StatEntries])
Parameter Name | Parameter Meaning |
---|---|
entPhysicalIndex |
Indicates the index of the physical entity. |
slotname |
Indicates the board name. |
Threshold |
Indicates the alarm threshold. |
DynEntries |
Indicates the number of dynamic ARP entries. |
StatEntries |
Indicates the number of static ARP entries. |
1. Run the display arp statistics command to view ARP entry statistics on the device and check whether there are more static ARP entries or dynamic ARP entries.
2. Run the display arp all command to identify the interface that has more ARP entries. Then run the display arp interface command to check ARP entries on the interface and determine whether these ARP entries are necessary for the interface.
3. Run the display current-configuration command to view static ARP entries and check whether these static ARP entries are necessary.
4. Run the display arp statistics command to check whether the number of ARP entries still continuously increases unexpectedly.
5. Collect the alarm information, log information, and configuration information, and contact Huawei technical support engineers.
6. End.